ASTM D7773-12
Standard Test Method for Determination of Volatile Inorganic Acids (HCl, HBr, and HNO3 ) Using Filter Sampling and Suppressed Ion Chromatography

Standard No.
ASTM D7773-12
Release Date
2012
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D7773-19
Latest
ASTM D7773-19
Scope

Exposure to inorganic acids in workplace air can cause irritations of the skin, eyes and respiratory tract, and exposure limits for hydrochloric acid, hydrobromic acid and nitric acid in air have been established to reduce exposure risks to potentially affected workers (1). Sampling and analytical methods for volatile inorganic acids are needed for exposure assessment and risk reduction purposes.

1.1 This test method is intended for use in the determination of the time-weighted average mass concentration of hydrogen chloride gas and hydrochloric acid mist, hydrogen bromide vapor and hydrobromic acid mist, and nitric acid vapor and mist in workplace air. The samples are collected on an alkali-impregnated quartz fiber filter and analyzed by ion chromatography. The method is also appropriate for measuring short term exposures.

1.2 This test method assumes that air samples are collected using appropriate and applicable ASTM International standards for sampling of workplace air.

1.3 The procedure is targeted for occupational and environmental hygiene monitoring purposes.

1.4 No detailed operating instructions are provided because of differences among various makes and models of suitable instruments. Instead, the analyst shall follow the instructions provided by the manufacturer of the particular instrument. This standard does not address comparative accuracy of different devices or the precision between instruments of the same make and model.

1.5 The values stated in SI units are to be regarded as the standard.

1.6 The practice contains notes, which are explanatory and not part of mandatory requirements of the standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D7773-12 Referenced Document

  • ASTM D1193 Standard Specification for Reagent Water
  • ASTM D4840 Standard Guide for Sample Chain-of-Custody Procedures
  • ASTM D5337 Standard Practice for Flow Rate for Calibration of Personal Sampling Pumps
  • ASTM D7035 Standard Test Method for Determination of Metals and Metalloids in Airborne Particulate Matter by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES)
  • ASTM D882 Standard Test Method for Tensile Properties of Thin Plastic Sheeting
  • ASTM E1370 Standard Guide for Air Sampling Strategies for Worker and Workplace Protection
  • ISO 1042 Laboratory glassware - One-mark volumetric flasks
  • ISO 648 Laboratory glassware - Single-volume pipettes
  • ISO 7708 Air quality - Particle size fraction definitions for health-related sampling

ASTM D7773-12 history

  • 2019 ASTM D7773-19 Standard Test Method for Determination of Volatile Inorganic Acids (HCl, HBr, and HNO3) Using Filter Sampling and Suppressed Ion Chromatography
  • 2012 ASTM D7773-12 Standard Test Method for Determination of Volatile Inorganic Acids (HCl, HBr, and HNO3 ) Using Filter Sampling and Suppressed Ion Chromatography
Standard Test Method for Determination of Volatile Inorganic Acids (HCl, HBr, and HNO<inf>3 </inf>) Using Filter Sampling and Suppressed Ion Chromatography