Scope

Test results give some indication of the apparent fiber length distribution in the sample tested.

Sieves are ideally suited to measure particle size and particle size distribution when all three axes of the particle are equidimensional or the particle is of spherical shape. Asbestos fibers differ considerably from these ideal conditions and, therefore, results depart from a true measure of fiber length and length distribution.

Characteristics that influence screening efficiency influence test results. Among these are moisture content, degree of fiberization, harshness, and the tendency for fibers to cling together, and of short fibers and fines to cling to longer fibers.

In spite of its shortcomings, this test method is particularly useful because of its simplicity and speed and satisfactory reproducibility.

The test is suitable for specification acceptance and manufacturing control.

1.1 This test method covers a dry screen analysis for asbestos fiber by means of a mechanical sieve shaker.

1.2 This test method is limited in its application to Group 4 and shorter chrysotile asbestos fiber samples as defined in Test Method D3639. However, some short amphibole asbestos fibers may be suitable for evaluation by this method.

1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.4 WarningBreathing of asbestos dust is hazardous. Asbestos and asbestos products present demonstrated health risks for users and for those with whom they come into contact. In addition to other precautions, when working with asbestos-cement products, minimize the dust that results. For information on the safe use of chrysoltile asbestos, refer to Safe Use of Chrysotile Asbestos: A Manual on Preventive and Control Measures.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety hazard, see 1.4. ^REFERENCE:

ASTM Standards:

D2590 Test Method for Sampling Chrysotile Asbestos

D2946 Terminology for Asbestos and Asbestosx02013;Cement Products

D3639 Test Method for Classification of Asbestos by Quebec Standard Test

D3879 Test Method for Sampling Amphibole Asbestos (Withdrawn)

E11 Specification for Woven Wire Test Sieve Cloth and Test Sieves

E177 Practice for Use of the Terms Precision and Bias in ASTM Test Methods

ASTM D2947/D2947M-88(2011)e1 Referenced Document

  • ASTM D2590 Standard Test Method for Sampling Chrysotile Asbestos*1998-04-19 Update
  • ASTM D2946 Standard Terminology for Asbestos and Asbestos-Cement Products*1998-04-19 Update
  • ASTM D3639 Standard Test Method for Classification of Asbestos by Quebec Standard Test*1992-04-19 Update
  • ASTM D3879 Standard Test Method for Sampling Amphibole Asbestos *1991-04-19 Update
  • ASTM E11 Standard Specification for Wire Cloth and Sieves for Testing Purposes*1995-04-19 Update
  • ASTM E177 Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods*1990-04-19 Update

ASTM D2947/D2947M-88(2011)e1 history

Standard Test Method for Screen Analysis of Asbestos Fibers



Copyright ©2024 All Rights Reserved