VDI 4300 Blatt 10-2008
Measurement of indoor air pollution - Measurement strategies for determination of mould fungi in indoor environment

Standard No.
VDI 4300 Blatt 10-2008
Release Date
2008
Published By
Association of German Mechanical Engineers
Status
Latest
VDI 4300 Blatt 10-2008
Replace
VDI 4300 Blatt 10-2006
Scope
This guideline describes the measurement strategy for the detection of moulds in indoor environments. The prime objective of this guideline is to provide assistance in locating mould sources. The methods and procedures presented do not allow any exposure assessments with regard to the room occupants. Furthermore, this guideline presents different sampling and analysis methods together with a description of their applicability and the interpretation of the measurement results. This guideline provides guidance for the field inspection and inventorying of the affected room or building and recommends suitable sampling and analysis methods to maximize the comparability of the measured data obtained for a given measurement objective. The application of this guideline requires the knowledge of guidelines VDI 4300 Part 1, VDI 4252 Part 2 and VDI 4253 Part 2.

VDI 4300 Blatt 10-2008 Referenced Document

  • DIN 
  • DIN 4108-7:2001 Thermal insulation and energy economy of buildings - Part 7: Airtightness of building, requirements, recommendations and examples for planning and performance
  • DIN EN 13098:2001 Workplace atmospheres - Guidelines for measurement of airborne microorganisms and endotoxin; German version EN 13098:2000
  • DIN EN 13829:2001 Thermal performance of buildings - Determination of air permeability of buildings - Fan pressurization method (ISO 9972:1996, modified); German version EN 13829:2000
  • DIN EN ISO 10211:2008 Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations (ISO 10211:2007); English version of DIN EN ISO 10211:2008-04
  • DIN EN ISO 16000-10:2006 Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test cell method (ISO 16000-10:2006); English version of DIN EN ISO 16000-10:2006-06
  • DIN EN ISO 16000-1:2006 Indoor air - Part 1: General aspects of sampling strategy (ISO 16000-1:2004); English version EN ISO 16000-1:2006-06
  • DIN EN ISO 16000-2:2006 Indoor air - Part 2: Sampling strategy for formaldehyde (ISO 16000-2:2004); English version of DIN EN ISO 16000-2:2006-06
  • DIN EN ISO 16000-5:2007 Indoor air - Part 5: Sampling strategy for volatile organic compounds (VOCs) (ISO 16000-5:2007)English version of DIN EN ISO 16000-5:2007-05
  • DIN EN ISO 16000-7:2007 Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations (ISO 16000-7:2007); English version of DIN EN ISO 16000-7:2007-11
  • DIN EN ISO 16000-9:2008 Indoor air - Part 9: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test chamber method (ISO 16000-9:2006); English version of DIN EN ISO 16000-9:2008-04

VDI 4300 Blatt 10-2008 history

  • 2008 VDI 4300 Blatt 10-2008 Measurement of indoor air pollution - Measurement strategies for determination of mould fungi in indoor environment
  • 2006 VDI 4300 Blatt 10-2006 Measurement of indoor air pollution - Measurement strategies for determination of mould fungi in indoor environment
Measurement of indoor air pollution - Measurement strategies for determination of mould fungi in indoor environment



Copyright ©2024 All Rights Reserved