VDI 2100 Blatt 2-2010
Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Active sampling by accumulation on activated charcoal - Solvent extraction

Standard No.
VDI 2100 Blatt 2-2010
Release Date
2010
Published By
Association of German Mechanical Engineers
Latest
VDI 2100 Blatt 2-2010
Replace
VDI 2100 Blatt 2-2001 VDI 2100 Blatt 2-2008
Scope
This guideline describes a total measurement procedure for the determination of halogenated and non-halogenated hydrocarbons in air in an analytical window from pentane to dodecane. The method described allows the determination of gaseous or vaporous organic compounds in air in the range of ambient concentrations. The advantages of the described method are the especial low blank values of the adsorption tubes, the low detection limit, caused by low volumes of the used solvent and the easy handling for the sampler and analyst. Furthermore one sample can be analysed many times.

VDI 2100 Blatt 2-2010 Referenced Document

  • DIN 32645:2008 Chemical analysis - Decision limit, detection limit and determination limit under repeatability conditions - Terms, methods, evaluation
  • DIN EN ISO 16017-1:2001 Indoor, ambiant and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling (ISO 16017-1:2000); German version EN ISO 16017-1:2000
  • DIN EN ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025:2005); German and English version EN ISO/IEC 17025:2005
  • DIN V ENV 13005:1999 Guide to the expression of uncertainty in measurement; German version ENV 13005:1999
  • VDI 1000-2010 VDI Guideline Work - Principles and procedures
  • VDI 2100 Blatt 1-2008 Gaseous ambient air pollution measurement - Indoor air pollution measurement - Gas chromatographic determination of organic compounds - Fundamentals
  • VDI 2100 Blatt 6-2008 Messen gasfoermiger Verbindungen in der Aussenluft - Messen von Innenraumluftverunreinigungen - Gaschromatografische Bestimmung organischer Verbindungen - Praktische Anleitung zur Bestimmung der Messunsicherheit
  • VDI 2449 Blatt 1-1995 Measurement methods test criteria - Determination of performance characteristics for the measurement of gaseous pollutants (immission)

VDI 2100 Blatt 2-2010 history

  • 2010 VDI 2100 Blatt 2-2010 Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Active sampling by accumulation on activated charcoal - Solvent extraction
  • 2001 VDI 2100 Blatt 2-2001 Messen gasfoermiger Verbindungen in der Aussenluft; Messen von Innenraumluftverunreinigungen - Gaschromatographische Bestimmung organischer Verbindungen - Aktive Probenahme durch Anreicherung auf Aktivkohle; Loesemittelextraktion
  • 1999 VDI 2100 Blatt 2-1999 Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Active sampling by accumulation on activated charcoal; solvent extraction
Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Active sampling by accumulation on activated charcoal - Solvent extraction