Scope
This standard specifies the detection of tetra to octachlorodibenzoparadioxin, tetra to octachlorodibenzofuran, and dioxin-like PCBs (hereinafter referred to as dioxins) in industrial water and factory wastewater using a gas chromatograph mass spectrometer (hereinafter referred to as GC). /MS) is specified. The GC/MS used here uses a capillary column as the gas chromatograph (GC) column, and is a double convergence mass spectrometer (MS) device with a resolution of 10,000 or higher. The detection limits for GC/MS in this standard vary depending on the equipment and measurement conditions, but are 0.1 pg for tetrachlorides and pentachlorides, 0.2 pg for hexachlorides and heptachlorides, and 0.5 pg for octachlorides. Dioxin-like PCBs are less than 0.2 pg.

JIS K 0312:2005 Referenced Document

  • JIS K 0094 Sampling methods for industrial water and industrial wastewater
  • JIS K 0114 General rules for gas chromatography*2012-02-20 Update
  • JIS K 0123 General rules for gas chromatography/mass spectrometry*2006-10-20 Update
  • JIS K 0211 Technical terms for analytical chemistry (General part)*2013-03-21 Update
  • JIS K 0215 Technical terms for analytical chemistry (Analytical instrument part)*2016-03-22 Update

JIS K 0312:2005 history

  • 2020 JIS K 0312:2020 Method for determination of tetra-through octachlorodibenzo-p-dioxins, tetra-through octachlorodibenzofurans and dioxin-like polychlorinatedbiphenyls in industrial water and waste water
  • 2009 JIS K 0312 ERRATUM 1:2009 ERRATUM
  • 2008 JIS K 0312 AMD 1:2008 Method for determination of tetra-through octachlorodibenzo-p-dioxins, tetra-through octachlorodibenzofurans and dioxin-like polychlorinatedbiphenyls in industrial water and waste water (Amendment 1)
  • 2005 JIS K 0312:2005 Method for determination of tetra-through octachlorodibenzo-p-dioxins, tetra-through octachlorodibenzofurans and dioxin-like polychlorinatedbiphenyls in industrial water and waste water
  • 1999 JIS K 0312:1999 Method for determination of tetra- through octa-chlorodibenzo-p-dioxins, tetra- through octa-chlorodibenzofurans and coplanar polychlorobiphenyls in industrial water and waste water