BS EN ISO 10893-12:2011 Non-destructive testing of steel tubes. Automated full peripheral ultrasonic thickness testing of seamless and welded (except submerged arc-welded) steel tubes
This part of ISO 10893 specifies requirements for the automated full peripheral ultrasonic testing of seamless
and welded steel tubes, with the exception of submerged arc-welded (SAW) tubes, for wall thickness
measurement. It specifies the testing method and corresponding calibration procedures.
NOTE 1 Full peripheral testing does not necessarily mean that 100 % of the tube surface is scanned.
NOTE 2 This test can be carried out simultaneously with full peripheral ultrasonic testing for the detection of laminar
imperfections (see ISO 10893-8) using the same ultrasonic transducers for both inspection requirements. Under these
circumstances, the minimum lamination size under detection determines the percentage of the tube surface for scanning,
according to ISO 10893-8.
This part of ISO 10893 can also be applicable to the testing of circular hollow sections.
This part of ISO 10893 is applicable to the thickness measurement of tubes with a specified outside diameter
equal to or greater than 25,4 mm and a minimum wall thickness of 2,6 mm, unless otherwise agreed on.
BS EN ISO 10893-12:2011 history
2020BS EN ISO 10893-12:2011+A1:2020 Non-destructive testing of steel tubes. Automated full peripheral ultrasonic thickness testing of seamless and welded (except submerged arc-welded) steel tubes
2011BS EN ISO 10893-12:2011 Non-destructive testing of steel tubes. Automated full peripheral ultrasonic thickness testing of seamless and welded (except submerged arc-welded) steel tubes
2000BS EN 10246-13:2000 Non-destructive testing of steel tubes - Automatic full peripheral ultrasonic thickness testing for seamless and welded (except submerged arc welded) steel tubes