GB/T 25890.5-2010
Railway applications.Fixed installations.DC switchgear.Part 5:Surge arresters and low-voltage limiters for specific use in d.c. system (English Version)

Standard No.
GB/T 25890.5-2010
Language
Chinese, Available in English version
Release Date
2011
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2024-03
Latest
GB/T 25890.5-2010
Replace By
GB/T 43022.1-2023
Scope
Chapters 4, 5 and 6 of this part of GB/T 25890 specify the requirements for surge arresters for ground installations of DC traction power supply systems. The arrester includes one or more non-linear resistance sheets, and one or more discharge gaps can be connected in series. Chapter 7 of this part of GB/T 25890 specifies the requirements for low-voltage limiters. In the ground device of the DC traction power supply system, when the voltage exceeds the specified value, the voltage limiter will be connected to some parts of the system to play a protective role. The low-voltage limiter can also form a self-recovery device together with contactors and other equipment. Voltage limiters generally do not provide surge protection. The main applications of low-voltage limiters are as follows: Connecting metal rails: Protecting track circuits; Grounding substation rails; Protecting cathodic circuits; Protecting cable shielding.

GB/T 25890.5-2010 Referenced Document

  • EN 50125-2:2002 Railway applications - Environmental conditions for equipment Part 2: Fixed electrical installations (Incorporating corrigendum June 2010)*2024-04-19 Update
  • GB/T 25890.1-2010 Railway applications.Fixed installations.DC switchgear.Part 1:General
  • IEC 60060-1:1989 High-voltage test techniques; part 1: general definitions and test requirements
  • IEC 60099-1:1991 Surge arresters; part 1: non-linear resistor type gapped surge arresters for a.c. systems
  • IEC 60099-4:2004 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
  • IEC 61643-1:2005 Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests

GB/T 25890.5-2010 history

  • 2011 GB/T 25890.5-2010 Railway applications.Fixed installations.DC switchgear.Part 5:Surge arresters and low-voltage limiters for specific use in d.c. system

GB/T 25890.5-2010 Railway applications.Fixed installations.DC switchgear.Part 5:Surge arresters and low-voltage limiters for specific use in d.c. system was changed to GB/T 43022.1-2023 Rail transit DC arresters and voltage limiting devices Part 1: Gapless metal oxide arresters.

Railway applications.Fixed installations.DC switchgear.Part 5:Surge arresters and low-voltage limiters for specific use in d.c. system

GB/T 25890.5-2010 -All Parts




Copyright ©2024 All Rights Reserved