This standard specifies the technical requirements, test methods, signs and instructions for use, packaging, transportation and storage of medical protective masks. This standard applies to self-priming filter medical protective masks that filter particulate matter in the air and block droplets, blood, body fluids, secretions, etc. in the medical working environment.
GB 19083-2010 Referenced Document
GB 15979-2002 Hygienic standard for disposable sanitary products
GB/T 14233.1-2008 Test methods for infusion,transfusion,injection equipments for medical use.Part 1:Chemical analysis methods
GB/T 14233.2-2005 Test methods for infusion,transfusion,injection equipment for medical use.Part 2:Biological test methods
GB/T 16886.10-2005 Biological evaluation of medical devices.Part 10:Tests for irritation and delayed-type hypersensitivity
GB/T 18664-2002 Selection,use and maintenance of respiratory protective equipment
GB/T 191 Packaging.Pictorial marking for handling of goods
GB/T 4745-1997 Textile fabrics--Determination of resistance to surface wetting--Spray test
GB/T 5549-1990 Surface active agents--Determination of surface tension by drawing up liquid films
YY/T 0691-2008 Clothing for protection against infectious agents.Medical face masks.Test method for resistance against penetration by synthetic blood(fixed volume,horizontally projected)
YY/T 0700-2008 Clothing for protection against contact with blood and body fluids.Determination of the resistance of protective clothing materials to penetration by blood and body fluids.Test method using synthetic blood