BS EN 61241-14:2004
Electrical apparatus for use in the presence of combustible dust - Selection and installation

Standard No.
BS EN 61241-14:2004
Release Date
2004
Published By
British Standards Institution (BSI)
Status
 2009-01
Replace By
BS EN 60079-14:2008
BS EN 60079-14:2009
Latest
BS EN 60079-14:2014
BS EN 60079-14:2009
Scope
This part of IEC 61241 specifies general requirements, additional to those required for basic electrical safety, for the selection of electrical apparatus and instruments and associated equipment, and for the installation of electrical apparatus to ensure safe use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. NOTE Various parts of the IEC 61241 series specify requirements for the design, construction and testing of electrical apparatus. Apparatus within the scope of this standard may also be subjected to additional requirements in other standards. The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protective measures which are not within the scope of this standard. This standard includes several types of protection that protect either from ingress of dust or have insufficient energy to cause ignition and provide surface temperature limitation. The principles of this standard may also be followed when combustible fibres or flyings cause a hazard. Where the apparatus is required to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional methods of protection may be necessary. The method used should not adversely affect the integrity of the enclosure. The requirements of this standard apply only to the use of electrical apparatus under normal or near normal atmospheric conditions. For other conditions, additional precautions may be necessary. For example, most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment. Other precautions might also be necessary in the use of electrical apparatus under conditions of extreme temperature and pressure. Such precautions are beyond the scope of this standard. This standard does not apply to dust from explosives which do not require atmospheric oxygen for combustion; neither does it apply to pyrophoric substances. This standard is not applicable to electrical apparatus intended for use in underground parts of mines, nor those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This standard does not take account of any risk due to an emission of flammable or toxic gas from the dust. The requirements specified in this standard are supplementary to and not alternative to any requirements that would apply to apparatus and installations in non-hazardous areas.

BS EN 61241-14:2004 history

  • 2014 BS EN 60079-14:2014 Explosive atmospheres. Electrical installations design, selection and erection
  • 2009 BS EN 60079-14:2008 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
  • 2004 BS EN 61241-14:2004 Electrical apparatus for use in the presence of combustible dust - Selection and installation
  • 1999 BS EN 50281-1-2:1999 Electrical apparatus for use in the presence of combustible dust - Electrical apparatus protected by enclosures - Selection, installation and maintenance
Electrical apparatus for use in the presence of combustible dust - Selection and installation