BS EN 61241-18:2004
Electrical apparatus for use in the presence of combustible dust. Protection by encapsulation 'mD'

Standard No.
BS EN 61241-18:2004
Release Date
2004
Published By
British Standards Institution (BSI)
Status
 2010-09
Replace By
BS EN 60079-18:2009
BS EN 60079-18:2010
Latest
BS EN 60079-18:2015
BS EN 60079-18:2010
Scope
This standard is to be read in conjunction with IEC 61241-0, the requirements of which apply to electrical apparatus protected by encapsulation and surface temperature limitation unless specifically excluded. This part of IEC 61241 is applicable to electrical apparatus protected by encapsulation type of protection "mD" and surface temperature limitation for use in areas where combustible dust may be present in quantities which could lead to a fire or explosion hazard. It specifies requirements for design, construction and testing of electrical apparatus, parts of electrical apparatus and Ex components where the rated voltage does not exceed 10 kV. NOTE 1 The actual working voltage may exceed the value given above by up to 10 %. NOTE 2 IEC 61241-14 ("Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation") gives guidance on the selection and installation of the apparatus. Apparatus within the scope of this standard may also be subjected to additional requirements in other standards - for example, IEC 60079-0 ("Electrical apparatus for explosive gas atmospheres - Part 0: General requirements"). The application of electrical apparatus in atmospheres which may contain explosive gas as well as combustible dust, whether simultaneously or separately, requires additional protective measures. This standard does not apply to dusts of explosives which do not require atmospheric oxygen for combustion, or to pyrophoric substances. This standard is not applicable to electrical apparatus intended for use in underground parts of mines as well as those parts of surface installations of such mines endangered by firedamp and/or combustible dust. This standard does not take account of any risk due to an emission of flammable or toxic gas from the dust. This standard does not include other types of protection and is only applicable to protection by encapsulation.

BS EN 61241-18:2004 history

  • 2015 BS EN 60079-18:2015 Explosive atmospheres. Equipment protection by encapsulation "m"
  • 2010 BS EN 60079-18:2009 Explosive atmospheres. Part 18: Equipment protection by encapsulation "m"
  • 2004 BS EN 61241-18:2004 Electrical apparatus for use in the presence of combustible dust. Protection by encapsulation 'mD'
Electrical apparatus for use in the presence of combustible dust. Protection by encapsulation mD