This standard specifies the silver nitrate volumetric method for the determination of hydrogen chloride in waste gas from stationary pollution sources. This standard is applicable to the determination of hydrogen chloride in waste gas from fixed pollution sources. The detection limit of this method is 0.03mg; when the sampling volume is 15L, the detection limit is 2mg/m.
HJ 548-2009 Referenced Document
GB/T 16157 "Determination of Particulate Matter in Exhaust from Stationary Pollution Sources and Sampling Methods of Gaseous Pollutants" Amendment No. 1*, 2017-12-29 Update
GB/T 6682 Water for analytical laboratory use.Specification and test methods
HJ/T 373 Technical specifications of quality assurance and quality control for monitoring of stationary pollution source (on trial)
HJ 548-2009 history
2016HJ 548-2016 Stationary source emissions-Determination of hydrogen chloride-Silver nitrate titration