- Standard No.
- HJ 503-2009
- Language
- Chinese, Available in English version
- Release Date
- 2009
- Published By
- Professional Standard - Environmental Protection
- Latest
-
HJ 503-2009
- Replace
-
GB/T 7490-1987
- Scope
- This standard specifies the 4-aminoantipyrine spectrophotometric method for the determination of volatile phenols in surface water, groundwater, drinking water, industrial wastewater and domestic sewage. Surface water, groundwater and drinking water should be measured by extraction spectrophotometry. The detection limit is 0.0003mg/L, the lower limit of determination is 0.001mg/L, and the upper limit of determination is 0.04mg/L. Industrial wastewater and domestic sewage should be measured by direct spectrophotometry. The detection limit is 0.01 mg/L, the lower limit of determination is 0.04 mg/L, and the upper limit of determination is 2.50 mg/L. For samples with a mass concentration higher than the upper limit of the standard determination, they can be measured after appropriate dilution.
HJ 503-2009 Referenced Document
- GB 7489-1987 Water guality-Determination of dissolved oxyqen-Iodometric method
- HJ/T 91 Technical Specifications Requirements for Monitoring of Surface Water and Waste Water
HJ 503-2009 history
- 2009 HJ 503-2009 Water quality.Determination of volatile phenolic compounds.4-AAP spectrophotometric method
HJ 503-2009 Water quality.Determination of volatile phenolic compounds.4-AAP spectrophotometric method has been changed from GB/T 7490-1987 Water quality--Determination of volatile phenolic compounds--After distillation by means of 4-AAP spectrophotometric method.