HJ 483-2009
Ambient air.Determination of sulfur dioxide.Tetrachloromercurate(TCM)-paraosaniline method (English Version)

Standard No.
HJ 483-2009
Language
Chinese, Available in English version
Release Date
2009
Published By
Professional Standard - Environmental Protection
Status
 2019-01
Replace By
HJ 483-2009(XG1-2018)
Latest
HJ 483-2009(XG1-2018)
Replace
GB/T 8970-1988
Scope
This standard specifies the tetrachloromercuric salt absorption-pararosaniline spectrophotometric method for the determination of sulfur dioxide in ambient air. This standard applies to the determination of sulfur dioxide in ambient air. When using 5ml of absorption liquid and the sampling volume is 30L, the detection limit of sulfur dioxide in the air is 0.005mg/m, the lower limit of determination is 0.020mg/m, and the upper limit of determination is 0.18g/m. When 50ml of absorbing liquid is used and the sampling volume is 288L, the detection limit of sulfur dioxide in the air is 0.005mg/m, the lower limit of determination is 0.020mg/m, and the upper limit of determination is 0.19mg/m.

HJ 483-2009 history

  • 0000 HJ 483-2009(XG1-2018)
  • 2009 HJ 483-2009 Ambient air.Determination of sulfur dioxide.Tetrachloromercurate(TCM)-paraosaniline method

HJ 483-2009 Ambient air.Determination of sulfur dioxide.Tetrachloromercurate(TCM)-paraosaniline method has been changed from GB/T 8970-1988 Air quality--Determination of sulfur dioxide in a ambient air--Tetrachlomercurate(TCM), pararosaniline.