This test method provides useful engineering information for evaluating the mechanical behavior of rigid electrical insulation at elevated temperature. When the proper exposure and test temperatures are chosen, depending on the material and end-use operating temperature, use the test method as one means of indicating relative thermal degradation of rigid insulating materials.
1.1 These test methods cover procedures for testing rigid electrical insulation normally manufactured in flat sheet or plate form. They are generally used as terminal boards, spacers, voltage barriers, and circuit boards.
Note 18212;For tests applying to vulcanized fibre reference needs to be made to Test Methods D619.
Note 28212;This standard resembles IEC 60893-2, Specification for Rigid Industrial Laminated Sheets Based On Thermosetting Resins for Electrical Purpose, Methods of Tests.
1.2 The test methods appear in the following sections:
Test | Sections | ASTM Test Method |
Acetone extractable matter | 83 to 84 | D494 |
Arc resistance | 47 | D495 |
Ash | 56 to 60 | ... |
Bonding strength | 49 to 54 | ... |
Burning rate and flame resistance | 61 to 75 | ... |
Compressive strength | 25 | D695 |
Conditioning | 4 | D6054 |
Dissipation factor | 34 to 40 | D669 |
Dielectric strength | 28 to 33 | D149 |
Expansion (linear thermal) | 76 | D696 |
Flexural properties | 12 to 24 | D790 |
Hardness (Rockwell) | 55 | D785 |