BS DD IEC TS 60695-11-3:2004
Fire hazard testing - Test flames - 500 W flames - Apparatus and confirmational test methods

Standard No.
BS DD IEC TS 60695-11-3:2004
Release Date
2004
Published By
British Standards Institution (BSI)
Latest
BS DD IEC TS 60695-11-3:2004
Replace
96/213288 DC:1996
Scope
Provides detailed requirements for the production of a 500 W nominal, pre-mixed type test flame. The approximate overall height is 125 mm. Two test flames are described: Method A may only be produced using methane whereas method C may be produced using either methane or propane. The main changes with respect to the previous edition are described below: - The introduction has been revised, - Test methods B and D have been withdrawn. Test methods A and C have been retained with their original letter designation, - Normative reference ISO 1337 has been withdrawn without a replacement by ISO/TC 26. The callout Cu-ETP UNS 11000 is the replacement for all references to ISO 1337. It is taken from ASTM B187-00 and describes high conductivity electrolytic copper, - A new Annex H has been added which provides access to equipment manufacturers and suppliers, - Alignment with other publications in the IEC 60695-11 series has been made, where appropriate. Has the status of a basic safety publication in accordance with IEC Guide 104.