IEC 61000-4-16:1998/AMD2:2009
Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz; Amendment 2

Standard No.
IEC 61000-4-16:1998/AMD2:2009
Release Date
2009
Published By
International Electrotechnical Commission (IEC)
Status
Replace By
IEC 61000-4-16:2011
Latest
IEC 61000-4-16:2015 RLV
Replace
IEC 77A/691/FDIS:2009
Scope
This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment to conducted@ common mode disturbances in the range d.c. to 150 kHz.The object of this standard is to establish a common and reproducible basis for testing electrical and electronic equipment with the application of common mode disturbances to power supply@ control@ signal and communication ports.This standard defines?C test voltage and current waveform;?C range of test levels;?C test equipment;?C test set-up;?C test procedures.For some types of ports@ for example ports intended to be used with highly balanced lines@ additional test provisions may be established by product committee specifications.The test is intended to demonstrate the immunity of electrical and electronic equipment when subjected to conducted@ common mode disturbances such as those originating from power line currents and return leakage currents in the earthing/grounding system.The disturbances produced by 400 Hz mains systems are not included in the scope of this standard.Actual interference due to these disturbance phenomena is relatively rare@ except in industrial plants. Product Committees should therefore consider whether there is a justification for applying this standard in their Product/Product Family standards (see also clause 3).This test is not relevant for equipment ports intended to be connected to short cables@ having a length less than 20 m or less.The immunity to harmonics and interharmonics@ including mains signalling@ on a.c. power ports (in differential mode) is not included in the scope of this standard and is covered by IEC 61000-4-13.The immunity to conducted disturbances generated by intentional radio-frequency transmitters is not included in the scope of this standard and is covered by IEC 61000-4-6.Some ITU-T Recommendations@ e.g. K17@ K20 and K21@ establish similar methods for testing the resistibility of equipment; however@ they are dedicated to telecommunication ports and deal with power induction at frequency of the a.c. mains or electric railways.Product Committees are advised to consider the Recommendations above@ as far as applicable@ in preparing their product standards.

IEC 61000-4-16:1998/AMD2:2009 history

  • 0000 IEC 61000-4-16:2015 RLV
  • 2011 IEC 61000-4-16:2011 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kKz
  • 2009 IEC 61000-4-16:1998/AMD2:2009 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz; Amendment 2
  • 2002 IEC 61000-4-16:2002 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques; Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kKz
  • 2001 IEC 61000-4-16:1998/AMD1:2001 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques; Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz; Amendment 1
  • 1998 IEC 61000-4-16:1998 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kKz