ASTM D6807-02(2009)
Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from2 to 100 S/cm

Standard No.
ASTM D6807-02(2009)
Release Date
2002
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D6807-17
Latest
ASTM D6807-17
Scope

CEDI devices can be used to produce deionized water from feeds of pretreated water. This test method permits the measurement of key performance capabilities of CEDI devices using a standard set of conditions. The data obtained can be analyzed to provide information on whether changes may have occurred in operating characteristics of the device independently of any variability in feed water characteristics or operating conditions. Under specific circumstances, the method may also provide sufficient information for plant design.

1.1 This test method covers the determination of the operating characteristics of continuous electrodeionization (CEDI) devices, indicative of deionization performance when a device is applied to production of highly deionized water from the product water of a reverse osmosis system. This test method is a procedure applicable to feed waters containing carbonic acid and/or dissolved silica and other solutes, with a conductivity range of approximately 2 to 100 microsiemens-cm-1.

1.2 This test method covers the determination of operating characteristics under standard test conditions of CEDI devices where the electrically active transfer media therein is predominantly regenerated.

1.3 The test method is not necessarily indicative of:

1.3.1 Long term performance on feed waters containing foulants and/or sparingly soluble solutes;

1.3.2 Performance on feeds of brackish water, sea water, or other high salinity feeds;

1.3.3 Performance on synthetic industrial feed solutions, pharmaceuticals, or process solutions of foods and beverages; or,

1.3.4 Performance on feed waters less than 2 μS/cm, particularly performance relating to organic solutes, colloidal or particulate matter, or biological or microbial matter.

1.4 The test method, subject to the limitations described, can be applied as either an aid to predict expected deionization performance for a given feed water quality, or as a method to determine whether performance of a given device has changed over some period of time. It is ultimately, however, the user's responsibility to ensure the validity of the test method for their specific applications.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D6807-02(2009) Referenced Document

  • ASTM D1125 Standard Test Methods for Electrical Conductivity and Resistivity of Water
  • ASTM D1129 Standard Terminology Relating to Water
  • ASTM D1293 Standard Test Methods for pH of Water
  • ASTM D2777 Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water
  • ASTM D4194 Standard Test Methods for Operating Characteristics of Reverse Osmosis Devices
  • ASTM D513 Standard Test Methods for Total and Dissolved Carbon Dioxide in Water
  • ASTM D859 Standard Test Method for Silica in Water

ASTM D6807-02(2009) history

  • 2017 ASTM D6807-17 Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from2 to 100 μS/cm
  • 2002 ASTM D6807-02(2009) Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from2 to 100 S/cm
  • 2002 ASTM D6807-02 Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from2 to 100 S/cm
Standard Test Method for Operating Performance of Continuous Electrodeionization Systems on Reverse Osmosis Permeates from2 to 100 S/cm



Copyright ©2024 All Rights Reserved