ASTM D511-09
Standard Test Methods for Calcium and Magnesium In Water

Standard No.
ASTM D511-09
Release Date
2009
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D511-14
Latest
ASTM D511-14(2021)e1
Scope

Calcium and magnesium salts in water are the primary components of water hardness which can cause pipe or tube scaling.

1.1 These test methods cover the determination of calcium and magnesium in water by complexometric titration and atomic absorption spectrometric procedures. Two test methods are included, as follows:

Sections
Test Method AComplexometric Titration 7 to 14
Test Method BAtomic Absorption Spectrometric15 to 23

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in 12.2.6 and 20.6.

7.1 This test method is applicable to most waters in a range from 1 to 1000 mg/L of calcium plus magnesium expressed as calcium, but may fail in the analysis of highly colored waters, brines, or waters that contain excessive amounts of metals. The upper and lower limits may be extended by either dilution or use of micro apparatus.

7.2 Data are not available to determine which matrices were used to obtain the precision and bias data, and it is the responsibility of the analyst to determine the acceptability of this test method for the matrix being analyzed.

16.1 This test method can be used to determine the concentration of calcium and magnesium in water. The determination of these ions in brackish water, sea water, and brines requires the use of the method of additions described in Section 22.

16.2 This test method is applicable for calcium concentrations in the range from 1.0 to 15 mg/L and magnesium concentrations from 0.25 to 3.5 mg/L. The upper limits can be increased to 1500 mg/L calcium and 350 mg/L magnesium by proper single dilution technique. Serial dilution technique should be used to further extend the limit.

16.3 The precision and bias were obtained on reagent water (1 % HCl). It is the responsibility of the analyst to determine the acceptability of this test method when analyzing untested matrices.

ASTM D511-09 Referenced Document

  • ASTM D1129 Standard Terminology Relating to Water
  • ASTM D1193 Standard Specification for Reagent Water
  • ASTM D2777 Standard Practice for Determination of Precision and Bias of Applicable Methods of Committee D-19 on Water
  • ASTM D3370 Standard Practices for Sampling Water from Closed Conduits
  • ASTM D4691 Standard Practice for Measuring Elements in Water by Flame Atomic Absorption Spectrophotometry
  • ASTM D4841 Standard Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents
  • ASTM D5810 Standard Guide for Spiking into Aqueous Samples 
  • ASTM D5847 Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis

ASTM D511-09 history

  • 2021 ASTM D511-14(2021)e1 Standard Test Methods for Calcium and Magnesium In Water
  • 2014 ASTM D511-14 Standard Test Methods for Calcium and Magnesium In Water
  • 2009 ASTM D511-09 Standard Test Methods for Calcium and Magnesium In Water
  • 2008 ASTM D511-08 Standard Test Methods for Calcium and Magnesium In Water
  • 2003 ASTM D511-03 Standard Test Methods for Calcium and Magnesium In Water
  • 1993 ASTM D511-93(1998) Standard Test Methods for Calcium and Magnesium In Water
Standard Test Methods for Calcium and Magnesium In Water



Copyright ©2024 All Rights Reserved