This part of IEC 61290 applies to optical fibre amplifiers (OFA) using active fibres, containing
rare-earth dopants, currently commercially available.
The object of this International Standard is to establish uniform requirements for accurate and
reliable measurements of the signal-spontaneous noise figure as defined in IEC 61291-1.
The test method independently detects amplified signal power and amplified spontaneous
emission (ASE) power by launching optical pulses into the OFA under test. The ASE level is
measured by synchronously measuring the power on an optical spectrum analyzer (OSA)
during the optical pulse off period. The average optical signal level is measured by random
sampling in the OSA.
BS EN 61290-10-2:2008 history
2009BS EN 61290-10-2:2009 Optical amplifiers. Test methods. Multichannel parameters. Pulse method using a gated optical spectrum analyzer
2009BS EN 61290-10-2:2008 Optical amplifiers – Test methods — Part 10-2: Multichannel parameters – Pulse method using a gated optical spectrum analyzer
2003BS EN 61290-10-2:2003 Optical amplifiers - Test methods - Multichannel parameters - Pulse method using a gated optical spectrum analyzer