This standard applies to devices for the connection of luminaires (DCL) intended for household
and similar purposes, for the electrical connection of fixed luminaires of class I or class II to final
circuits rated at not more than 16 A without providing a mechanical support for the luminaire.
DCLs are intended for use according to their IP rating per EN 60529.
Outlets have an earthing contact and a rated current of 6 A, plugs are rated at 6 A.
The rated voltage is 250 V at 50 Hz.
NOTE 1 This standard does not cover integrated DCL-plugs (under consideration).
This standard can also be applied to types other than those with standardised interface.
NOTE 2 Void.
DCL plugs and DCL outlets complying with this standard are suitable for use under the
following conditions:
– an ambient temperature not normally exceeding 25 °C, but occasionally reaching 35 °C;
NOTE 3 The effect of the heat generated by the luminaire may affect the ambient temperature local to the
DCL.
– a temperature not exceeding 70 °C at the terminals of the DCL outlet including the effect
of heat generated by the luminaire and the passage of current.
NOTE 4 The requirements and tests of this standard may also be used as a guide when testing DCL's which
have different interface configurations or ratings.
EN 61995-1:2008 history
2021EN 61995-1:2008/A11:2021 Devices for the connection of luminaires for household and similar purposes - Part 1: General requirements
2018EN 61995-1:2008/PRAA:2018 Devices for the connection of luminaires for household and similar purposes - Part 1: General requirements
2008EN 61995-1:2008 Devices for the connection of luminaires for household and similar purposes — Part 1: General requirements