ISO 16000-6:2004
Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID

Standard No.
ISO 16000-6:2004
Release Date
2004
Published By
International Organization for Standardization (ISO)
Status
Replace By
ISO 16000-6:2011
Latest
ISO 16000-6:2021
Scope
This part of ISO 16000 specifies a method for determination of volatile organic compounds (VOCs) in indoor air and in air sampled for the determination of the emission of VOCs from building materials using test chambers and cells. The method is based on use of Tenax TA sorbent with subsequent thermal desorption and gas chromatographic analysis[1]. The method is applicable to the measurement of non-polar and slightly polar VOCs in a concentration range of sub-microgram per cubic metre to up to several milligrams per cubic metre. Using the principles described in this method, some very volatile compounds (VVOC) and semivolatile organic compounds (SVOC) can also be analysed. note: 1) Tenas TA is the trade name of a product manufactured by Supelco, Inc. This information is given for the convenience of this International Standard and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to the same results.

ISO 16000-6:2004 Referenced Document

  • ISO 16000-1 Indoor air - Part 1: General aspects of sampling strategy*2004-07-01 Update
  • ISO 16017-1 Indoor, ambiant and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 1: Pumped sampling

ISO 16000-6:2004 history

  • 2021 ISO 16000-6:2021 Indoor air — Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
  • 2011 ISO 16000-6:2011 Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID
  • 2004 ISO 16000-6:2004 Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID
Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS/FID



Copyright ©2024 All Rights Reserved