BS EN 50264-3-2:2008
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions — Multicore cables

Standard No.
BS EN 50264-3-2:2008
Release Date
2008
Published By
British Standards Institution (BSI)
Latest
BS EN 50264-3-2:2008
Scope
EN 50264-3-2 specifies requirements for, and constructions and dimensions of, multicore cables of the following types and voltage ratings: • 300/500 V screened or unscreened (1 mm2, 1,5 mm2 and 2,5 mm2, number of cores from 2 to 40); • 0,6/1 kV screened or unscreened, (1,5 mm2 to 50 mm2, 2, 3 and 4 cores). NOTE Not all conductor sizes or number of cores are specified for every type. All cables have class 5 tinned copper conductors to EN 60228, halogen-free insulation and halogen-free sheath. They are for use in railway rolling stock as fixed wiring, or wiring where limited flexing in operation is encountered. The requirements provide for a continuous conductor temperature not exceeding 90 °C and a maximum temperature for short circuit conditions of 200 °C based on a duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. EN 50264-3-2 should be read in conjunction with Part 1 “General requirements”.

BS EN 50264-3-2:2008 Referenced Document

  • EN 10002-1 Metallic Materials - Tensile Testing - Part 1: Method of Test at Ambient Temperature
  • EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
  • EN 50266-2-4 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Part 2-4: Procedures - Category C
  • EN 50266-2-5 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Part 2-5: Procedures - Small Cables - Category D
  • EN 50305:2002 Railway Applications - Railway Rolling Stock Cables Having Special Fire Performance - Test Methods
  • EN 50334 Marking by Inscription for the Identification of Cores of Electric Cables
  • EN 60228 Conductors of insulated cables IEC 60228:2004; Supersedes HD 383 S2:1986 + A1:1989 + A2:1993
  • EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R (Remains Current)
  • EN 60811-1-1:1995 Insulating and Sheathing Materials of Electric Cables Common Test Methods Part 1: General Application Section 1: Measurement of Thickness and Overall Dimensions Tests for Determining the Mechanical Properties
  • EN 60811-1-3:1995 Insulating and Sheathing Materials of Electric Cables Common Test Methods Part 1: General Application Section 3. Methods for Determining the Density Water Absorption Tests - Shrinkage Test
  • EN 60811-1-4:1995 Insulating and Sheathing Materials of Electric Cables - Common Test Methods - Part 1-4: General Application - Tests at Low Temperature
  • EN 60811-2-1:1998 Insulating and Sheathing Materials of Electric and Optical Cables - Common Test Methods - Part 2-1: Methods Specific to Elastomeric Compounds - Ozone Resistance@ Hot Set and Mineral Oil Immersion Tests
  • EN 61034-2 Measurement of smoke density of cables burning under defined conditions Part 2: Test procedure and requirements (Incorporates Amendment A1: 2013)
  • HD 308 Identification and Use of Cores of Flexible Cables

BS EN 50264-3-2:2008 history

  • 2008 BS EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions — Multicore cables
Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions — Multicore cables



Copyright ©2024 All Rights Reserved