This standard is applicable to tubular fluorescent lamps and other gas discharge lamps (self-ballasted lamps) for general lighting in households and similar places, which integrate control start-up and stable ignition components. This standard specifies the safety and interchangeability requirements for this kind of lamp, as well as the test method and the conditions for checking its eligibility. The scope of application is as follows: - rated power not exceeding 60W; - rated voltage 100 V ~ 250 V; - Edison screw lamp or bayonet lamp. The requirements of this standard relate only to type testing. Methods for inspection of whole products and batches of products are under consideration.
IEC 60061-1 Lamp caps and holders together with gauges for the control of interchangeability and safety – Part 1: Lamp caps
IEC 60061-3 Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 3: Gauges
IEC 60695-2-1:1980 Fire hazard testing - Part 2: Test methods - Glow-wire test and guidance
QB/T 2512 Methods of measurement for lamp cap temperature rise
GB 16844-2008 history
2023GB/T 16844-2023 Safety specifications for self-ballasted fluorescent lamps for general lighting
2008GB 16844-2008 Self-ballasted lamps for general lighting services.Safety requirements
1997GB 16844-1997 Self-ballasted lamps for general lighting services--Safety requirements
GB 16844-2008 Self-ballasted lamps for general lighting services.Safety requirements was changed to GB/T 16844-2023 Safety specifications for self-ballasted fluorescent lamps for general lighting.