GB/T 21929-2008
Test method for flash point by tag closed cup tester (English Version)

Standard No.
GB/T 21929-2008
Language
Chinese, Available in English version
Release Date
2008
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 21929-2008
Scope
1.1 This standard is applicable to the determination of viscosity less than 5.5 mm2/s (cSt) at 40°C (104°F) by Tiger manual and automatic closed mouth tester, or less than 9.5 mm2/s(cSt) and the flash point of liquids with a flash point lower than 93°C (200°F). 1.1.1 The viscosity is not less than 5.5 mm2/s(cSt) at 40°C (104°F), and not less than 9.5 mm2/s(cSt) at 25°C (77°F). ), liquids with a flash point not lower than 93°C (200°F), and closed-cup flash points of liquids that tend to form surface films or contain suspended solids under the test conditions are determined by the ASTM D93 test method. 1.1.2 For the determination of the flash point of thinned asphalt according to ASTM D1310 and ASTM D3143. 1.2 This test method can be used to determine and describe the reaction of materials, products or compositions to heat and flame under controlled laboratory conditions, and cannot be used to describe or evaluate the fire hazard of materials, products or compositions under actual fire conditions sex. The results of this test can be used as the elements for evaluating the fire hazard, and the evaluation of the fire hazard should take into account all the factors related to the fire hazard in the actual end use. 1.3 Relevant standards include ASTM D93, ASTM D1310, ASTM D3828, ASTM D3278 and ASTM D3941 test methods. 1.4 The data in the SI unit system is used as the standard, and the values in brackets are for reference only. 1.5 This standard involves certain hazardous materials, operations and equipment, but it is not intended to make recommendations on all safety issues related to this. Therefore, it is necessary for standard users to establish appropriate safety and protection measures and establish appropriate operating procedures before use. For specific hazard instructions see 8.2, 8.3, 9.5, 12.5 and consult the Safety Data Sheet.

GB/T 21929-2008 Referenced Document

  • ASTM D1310 Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus
  • ASTM D3143 Standard Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus (Withdrawn 2007)*2010-12-31 Update
  • ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
  • ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester
  • ASTM D3941 Standard Test Method for Flash Point by the Equilibrium Method With a Closed-Cup Apparatus
  • ASTM D4057 Standard Practice for Manual Sampling of Petroleum and Petroleum Products
  • ASTM D6299 Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance*2023-07-01 Update
  • ASTM D6300 Standard Practice for Determination of Precision and Bias Data for Use in Test Methods for Petroleum Products and Lubricants
  • ASTM D93 Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester
  • ASTM E1 Standard Specification for ASTM Thermometers
  • ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods

GB/T 21929-2008 history

Test method for flash point by tag closed cup tester