ASTM E1413-07
Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration

Standard No.
ASTM E1413-07
Release Date
2007
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM E1413-13
Latest
ASTM E1413-19
Scope

This practice is useful for preparing extracts from fire debris for later analysis by gas chromatography, GC/MS, or GC/IR.

This is a very sensitive separation procedure, capable of isolating quantities smaller than 0.1 μL of ignitable liquid residue from a sample.

4.2.1 Actual recovery will vary, depending on several factors, including adsorption temperature, container size, and competition from the sample matrix.

This is a potentially destructive technique. Portions of the sample subjected to this procedure may not be suitable for re-sampling. Therefore, a portion of the sample extract should be saved for potential future analysis. Consider using passive headspace concentration as described in Practice E 1412.

1.1 This practice describes the procedure for separation of small quantities of ignitable liquid residues from fire debris samples using the absorption/elution method of headspace concentration.

1.2 Both positive and negative pressure systems are described.

1.3 While this practice is suitable for successfully extracting ignitable liquid residues over the entire range of concentration, the headspace concentration methods are best used when a high level of sensitivity is required due to a very low concentration of ignitable liquid residues in the sample.

1.4 Alternate separation and concentration procedures are listed in Section 2.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM E1413-07 history

  • 2019 ASTM E1413-19 Standard Practice for Separation of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration onto an Adsorbent Tube
  • 2013 ASTM E1413-13 Standard Practice for Separation of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration
  • 2007 ASTM E1413-07 Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration
  • 2006 ASTM E1413-06 Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration
  • 2000 ASTM E1413-00(2005) Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration
  • 2000 ASTM E1413-00 Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Dynamic Headspace Concentration



Copyright ©2024 All Rights Reserved