These test methods for the chemical analysis of metals and alloys are primarily intended to test such materials for compliance with compositional specifications. It is assumed that all who use these test methods will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that work will be performed in a properly equipped laboratory.
Note8212;Shaded areas are suitable for sampling.
FIG. 1 Type A and Type B Disks1.1 These test methods cover the chemical analysis of aluminum and aluminum-base alloys having compositions within the following limits:
Beryllium, ppm | 0.3 to 100 |
Bismuth, % | 0.02 to 1.0 |
Boron, % | 0.005 to 0.060 |
Cadmium, % | 0.001 to 0.50 |
Chromium, % | 0.01 to 1.0 |
Copper, % | 0.01 to 20.0 |
Gallium, % | 0.001 to 0.05 |
Iron, % | 0.01 to 3.0 |
Lead, % | 0.01 to 1.0 |
Lithium, % | 0.001 to 4.0 |
Magnesium, % | 0.002 to 12.0 |
Manganese, % | 0.005 to 2.0 |
Nickel, % | 0.01 to 4.0 |
Silicon, % | 0.05 to 20.0 |
Tin, % | 0.03 to 1.0 |
Titanium, % | 0.002 to 0.30 |
Vanadium, % | 0.002 to 0.16 |
Zinc, % | 0.003 to 12.0 |
Zirconium, % | 0.01 to 0.30 |
1.2 The analytical procedures appear in the following order:
Sections | |
Beryllium by Argon Plasma Optical Emission Spectroscopy | 283 to 292 |
Beryllium by the Morin (Fluorometric) Test Method | 8-19 |
Bismuth by the Thiourea (Photometric) Method | 1a |
Bismuth and Lead by the Atomic Absorption Test Method | 188 to 198 |
Boron by the Carmine (Photometric) Test Method | 30 to 38 |
Cadmium by the Atomic Absorption Test Method | 167 to 177 |
Chromium: | |
Diphenylcarbazide (Photometric) Test Method | 39 to 47 |
Persulfate Oxidation (Titrimetric) Test Method | 1b |
Chromium by the Atomic Absorption Test Method | 199 to 209 |
Copper and Lead by the Electrolytic (Gravimetric) Test Method | 1c |
Copper and Zinc by the Atomic Absorption Test Method | 210 to 220 |
Copper by the Electrolytic (Gravimetric) Test Method | 303 to 311 |
Copper by the Neocuproine (Photometric) Test Method | 1a |
Gallium by the Ion Exchange-Atomic Absorption Test Method | 312 to 323 |
Iron by the 1,10-Phenanthroline (Photometric) Method | 73 to 81 |
Iron and Manganese by the Atomic Absorption Method | 221 to 231 |
Lithium by the Atomic Absorption Test Method | 324 to 334 |
Magnesium: | |
Pyrophosphate (Gravimetric) Method | 1 b |
Ethylenediamine Tetraacetate (Titrimetric) TestMethod | 88 to 93 |
Magnesium by the Atomic Absorption Test Method | 232 to 242 |
Manganese by the Periodate (Photometric) Test Method | 293 to 302 |
Nickel: | |
Dimethylglyoxime (Photometric) Test Method | 1......
ASTM E34-94(2002) history