ASTM D5116-06
Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products

Standard No.
ASTM D5116-06
Release Date
2006
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D5116-10
Latest
ASTM D5116-17
Scope
DESIG: D5116 06 ^TITLE: Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products ^SCOPE:

1. Scope

1.1 This guide provides guidance on determination of emissions of organic compounds from indoor materials and products using small-scale environmental test chambers.

1.2 This guide pertains to chambers that fully enclose a material specimen to be tested and does not address other emission chamber designs such as emission cells (see instead Practice D 7143).

1.3 As an ASTM standard, this guide describes options, but does not recommend specific courses of action. This guide is not a standard test method and must not be construed as such.

1.4 The use of small environmental test chambers to characterize the organic emissions of indoor materials and products is still evolving. Modifications and variations in equipment, testing procedures, and data analysis are made as the work in the area progresses. For several indoor materials, more detailed ASTM standards for emissions testing have now been developed. Where more detailed ASTM standard practices or methods exist, they supersede this guide and should be used in its place. Until the interested parties agree upon standard testing protocols, differences in approach will occur. This guide will continue to provide assistance by describing equipment and techniques suitable for determining organic emissions from indoor materials. Specific examples are provided to illustrate existing approaches; these examples are not intended to inhibit alternative approaches or techniques that will produce equivalent or superior results.

1.5 Small chambers have obvious limitations. Normally, only samples of larger materials (for example, carpet) are tested. Small chambers are not applicable for testing complete assemblages (for example, furniture). Small chambers are also inappropriate for testing combustion devices (for example, kerosene heaters) or activities (for example, use of aerosol spray products). For some products, small chamber testing may provide only a portion of the emission profile of interest. For example, the rate of emissions from the application of high solvent materials (for example, paints and waxes) via brushing, spraying, rolling, etc. are generally higher than the rate during the drying process. Small chamber testing can not be used to evaluate the application phase of the coating process. Large (or full-scale) chambers may be more appropriate for many of these applications. For guidance on full-scale chamber testing of emissions from indoor materials refer to Practice D 6670.

1.6 This guider does not provide specific guidance for the selection of sampling media or for the analysis of volatile organics. This information is provided in Practice D 6196.

1.7 The guide does not provide specific guidance for determining emissions of formaldehyde from pressed wood products, since large chamber testing methods for such emissions are well developed and widely used. For more information refer to Test Method E 1333. It is possible, however, that the guide could be used to support alternative testing methods.

1.8 This guide is applicable to the determination of emissions from products and materials that may be used indoors. The effects of the emissions (for example, toxicity) are not addressed and are beyond the scope of the guide. Guide D 6485 provides an example of the assessment of acute and irritant effects of VOC emissions for a given material. Specification of "target" organic species of concern is similarly beyond the scope of this guide. As guideline levels for specific indoor contaminants develop, so too will emission test protocols to provide relevant information. Emissions databases and material labeling schemes will also be expected to adjust to reflect the current state of knowledge.

1.9 Specifics related to the acquisition, handling, conditioning, pr......

ASTM D5116-06 Referenced Document

  • ASTM D1193 Standard Specification for Reagent Water
  • ASTM D1356 Standard Terminology Relating to Sampling and Analysis of Atmospheres*2024-04-19 Update
  • ASTM D1914 Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres
  • ASTM D3195 Standard Practice for Rotameter Calibration
  • ASTM D3609 Standard Practice for Calibration Techniques Using Permeation Tubes
  • ASTM D3686 Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)
  • ASTM D3687 Standard Practice for Analysis of Organic Compound Vapors Collected by the Activated Charcoal Tube Adsorption Method
  • ASTM D6196 Standard Practice for Selection of Sorbents and Pumped Sampling/Thermal Desorption Analysis Procedures for Volatile Organic Compunds in Air
  • ASTM D6485 Standard Guide for Risk Characterization of Acute and Irritant Effects of Short-Term Exposure to Volatile Organic Chemicals Emitted from Bedding Sets
  • ASTM D6670 Standard Practice for Full-Scale Chamber Determination of Volatile Organic Emissions from Indoor Materials/Products
  • ASTM D7143 Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products
  • ASTM E1333 Standard Test Method for Determining Formaldehyde Concentrations in Air and Emission Rates from Wood Products Using a Large Chamber
  • ASTM E355 Standard Practice for Gas Chromatography Terms and Relationships*2024-04-19 Update

ASTM D5116-06 history

  • 2017 ASTM D5116-17 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products
  • 2010 ASTM D5116-10 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products
  • 2006 ASTM D5116-06 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products
  • 1997 ASTM D5116-97 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products
Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products



Copyright ©2024 All Rights Reserved