1.1 These test methods cover the determination of dissolved and total recoverable cadmium in water and wastewater by atomic-absorption spectrophotometry and differential pulse anodic stripping voltammetry. Four test methods are included as follows:
Concentration Range | Sections | |
Test Method A8212;Atomic Absorption, Direct | 0.05 to 2.0 mg/L | 7 to 15 |
Test Method B8212;Atomic Absorption, Chelation-Extraction | 5 to 200 956;g/L | 16 to 24 |
Test Method C8212;Differential PulseAnodic Stripping Voltammetry | 1 to 100 956;g/L | 25 to 34 |
Test Method D8212;Atomic Absorption, Graphite Furnace | 2 to 10 956;g/L | 35 to 43 |
1.2 Test Method B can be used to determine cadmium in brines. It is the user's responsibility to ensure the validity of these test methods for waters of untested matrices.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.