ASTM D3759/D3759M-05
Standard Test Method for Tensile Strength and Elongation of Pressure-Sensitive Tapes

Standard No.
ASTM D3759/D3759M-05
Release Date
2005
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D3759/D3759M-05(2011)
Latest
ASTM D3759/D3759M-05(2019)
Scope

This test method provides information that can be used in material specifications for product design and quality assurance applications. It can be used in comparing different products.

The use of this test method must be related to the purpose for which the test is performed. One purpose is for determining the relative strength of the tape in the size in which it is purchased or used. Another purpose is to identify or characterize a particular backing material.

5.2.1 The test may be performed on the tape as-received, that is, without cutting the material to a specimen width less than the as-received width. Usually tapes wider than 48 mm [2 in.] are not tested due principally to the limitations of equipment. Tapes as narrow as approximately 3 mm [0.125 in.] can be tested.

5.2.2 The test may be performed on a specimen cut from within the sample material boundaries using a sharp razor cutter, such as that defined in Section 6. This method is usually used for material characterization, determining quality of conformance, and for specification compliance.

Stretch characteristics of elongation at break or force to a specified elongation can be related to the tapersquo;intended use or for identifying or characterizing a material.

1.1 This test method covers the measurement of tensile strength at break (breaking strength) and stretch properties (elongation) for pressure-sensitive tapes and labels. It includes procedures for machine direction and cross direction, for high-strength filament reinforced backings and for high stretch backings. It also includes a procedure for obtaining force ("F" value) in conjunction with a specified elongation. These procedures employ a constant-rate-of-extension (CRE)-type testing machine.

1.2 The values stated in either SI or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; conversions between measurement systems must be conducted carefully.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D3759/D3759M-05 history




Copyright ©2024 All Rights Reserved