ASTM D5202-02
Standard Test Method for Determining Triaxial Compression Creep Strength of Chemical Grouted Soils

Standard No.
ASTM D5202-02
Release Date
2002
Published By
American Society for Testing and Materials (ASTM)
Status
Replace By
ASTM D5202-08
Latest
ASTM D5202/D5202M-16
Scope

Data from these tests may be used for structural design purposes. Adequate safety factors, based on engineering judgment must be determined by the user.

Note 28212;Sampling procedures for in-situ specimens have a major influence on test results. Specimens carefully trimmed in the laboratory from large block samples taken in the field have the least chance of fracturing prior to testing. Sample preparation methods of laboratory-fabricated specimens also have a major influence on test results. Specimens should be fabricated in accordance with Test Method D 4320.

Note 38212;The quality of the result produced by this test method is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D 3740 are generally considered capable of competent and objective testing/sampling/inspection/etc. Users of this test method are cautioned that compliance with Practice D 3740 does not in itself assure reliable results. Reliable results depend on many factors; Practice D 3740 provides a means of evaluating some of those factors.

1.1 This test method covers the determination of long- term strength and deformation of a cylindrical specimen of either a (undisturbed) field sample or laboratory-fabricated chemical grouted soil when it is sheared undrained in compression under a constant sustained load. Note 1The voids of chemical grouted soils are most often substantially filled with grout. Thus, pore pressures are unlikely to develop. This test method is not applicable to partially grouted soils in which substantial pore pressures may develop. If pore pressures must be measured, reference is made to Test Method D 4767 for equipment and procedures.

1.2 This test method provides data useful in determining strength and deformation properties of chemical grouted soils subjected to sustained loads. Mohr strength envelopes may also be determined.

1.3 The determination of strength envelopes and the development of relationships to aid in interpreting and evaluating test results are left to the engineer or office requesting the test.

1.4 The values stated in either SI or inch-pound units shall be regarded separately as standard. The values in each system may not be exact equivalents, therefore, each system must be used independently of the other, without combining values in any way.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ASTM D5202-02 history

  • 2016 ASTM D5202/D5202M-16 Standard Test Method for Determining Triaxial Compression Creep Strength of Chemically Grouted Soils
  • 2008 ASTM D5202-08 Standard Test Method for Determining Triaxial Compression Creep Strength of Chemical Grouted Soils
  • 2002 ASTM D5202-02 Standard Test Method for Determining Triaxial Compression Creep Strength of Chemical Grouted Soils
  • 1997 ASTM D5202-91(1997) Standard Test Method for Determining Triaxial Compression Creep Strength of Chemical Grouted Soils



Copyright ©2024 All Rights Reserved