EJ/T 1212.10-2008 Test methods for analysis of sintered gadolinium oxide-uranium dioxide pellets.Part10: Determination of carbon by high-frequency inductive combustion-infrared detection method (English Version)
This part specifies the method summary, reagents and materials, instruments, samples, analysis steps, result calculation and method precision for the determination of carbon element in sintered gadolinium oxide-uranium dioxide (GdO-UO) pellets. This section applies to the determination of carbon content in GdO-UO pellets. It is also suitable for the determination of carbon content of GdO-UO powder. When the sampling amount is 0.5g, the mass fraction range of measured carbon is (10~1000) μg/g.
EJ/T 1212.10-2008 history
2008EJ/T 1212.10-2008 Test methods for analysis of sintered gadolinium oxide-uranium dioxide pellets.Part10: Determination of carbon by high-frequency inductive combustion-infrared detection method