This part of GB/T 10002 stipulates the product classification, technical requirements, test methods, inspection rules and signs of rigid polyvinyl chloride pipe fittings for water supply, which are made of polyvinyl chloride resin as the main raw material and formed by injection molding and pipe bending. , packaging, transportation, storage. This section applies to rigid polyvinyl chloride pipe fittings used in buildings or buried water supply. It is used together with GB/T 10002.1 "Rigid polyvinyl chloride (PVC-U) pipes for water supply". The fittings specified in this standard are suitable for conveying drinking water and water for general purposes under pressure, the water temperature does not exceed 45 ℃. This section does not apply to hot gas welding and hot plate welding pipe fittings.
GB/T 10002.2-2003 history
2023GB/T 10002.2-2023 Rigid polyvinyl chloride (PVC-U) pipe fittings for water supply
2006GB/T 10002.1-2006 Unplasticized poly (vinyl chloride) (PVC-U) pipes for water supply
2003GB/T 10002.2-2003 Fittings made of unplasticized poly(vinyl chloride)(PVC-U)for water supply
0000 GB/T 10002.2-1988
GB/T 10002.2-2003 Fittings made of unplasticized poly(vinyl chloride)(PVC-U)for water supply was changed to GB/T 10002.1-2006 Unplasticized poly (vinyl chloride) (PVC-U) pipes for water supply.