This standard sets out the method for determining the relative quantity of mixing water that will bleed from a sample of freshly mixed concrete under the conditions of the test. The standard applies only to concrete in which the maximum aggregate size is 40 mm or less.
The standard provides for compaction of the sample either by hand tamping or by vibration.
NOTE: The results obtained will be dependent on the compaction method used.