This part of IEC 62127 specifies methods of use of calibrated hydrophones for the
measurement in liquids of acoustic fields generated by ultrasonic medical equipment operating
in the frequency range up to 40 MHz.
IEC 62127-1:2007 Referenced Document
IEC 60050-801:1994 International Electrotechnical Vocabulary - Chapter 801: Acoustics and electroacoustics
IEC 60565 Underwater acoustics - Hydrophones - Calibration in the frequency range 0,01 Hz to 1 MHz
IEC 61689 Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz*, 2022-03-08 Update
IEC 61828 Ultrasonics - Transducers - Definitions and measurement methods regarding focusing for the transmitted fields*, 2020-12-15 Update
IEC 61847 Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics
IEC 62127-2 Ultrasonics - Hydrophones - Part 2: Calibration for ultrasonic fields up to 40 MHz*, 2017-03-01 Update
IEC 62127-3 Ultrasonics — Hydrophones — Part 3: Properties of hydrophones for ultrasonic fields*, 2022-12-19 Update
ISO ISO IEC 27001-2013 cor2-2015 technical errata*, 2024-04-18 Update
ISO 16269-6:2005 Statistical interpretation of data - Part 6: Determination of statistical tolerance intervals
IEC 62127-1:2007 history
0000 IEC 62127-1:2022 RLV
2013IEC 62127-1:2007/AMD1:2013 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz; Amendment 1
2013IEC 62127-1:2013 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz
2008IEC 62127-1:2007/COR1:2008 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz; Corrigendum 1
2007IEC 62127-1:2007 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz
IEC 62127-1:2007 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz has been changed from IEC 60866:1987 Characteristics and calibration of hydrophones for operation in the frequency range O.5 MHz to 15 MHz.
IEC 62127-1:2007 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz has been changed from IEC 61101:1991 The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0,5 MHz to 15 MHz.
IEC 62127-1:2007 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz has been changed from IEC 61102:1991 Measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0,5 MHz to 15 MHz.
IEC 62127-1:2007 Ultrasonics - Hydrophones - Part 1: Measurement and characterization of medical ultrasonic fields up to 40 MHz has been changed from IEC 62092:2001 Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz.