JJG 1026-2007
Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography (CT) (English Version)

Standard No.
JJG 1026-2007
Language
Chinese, Available in English version
Release Date
2007
Published By
National Metrological Verification Regulations of the People's Republic of China
Status
 2018-05
Replace By
JJG 961-2017
Latest
JJG 961-2017
Scope
This calibration procedure is applicable to the calibration of X-ray radiation sources of medical diagnostic spiral computerized imaging devices (CT) that are newly installed, in use, and after repairs of components that affect imaging performance.

JJG 1026-2007 Referenced Document

  • GB 3100-1993 SI units and recommendations for the use of their multiples and of certain other units
  • GB 3101-1993 Quantities and units--General principles
  • GB 9706.18-2000 Medical electrical equipment-Part 2:Particular requirements for the safety of X-ray equipment for computed tomography
  • GB/T 10149-1988 Terminology and symbol for medical X-ray equipment
  • GB/T 17006-1997 Evaluation and routine testing in medical imaging departments--Part 2-6: Constancy tests--X-ray equipment for computed tomography
  • GB/T 17589-1998 Specification of image quality assurance test for X-ray equipment for computed tomography
  • GB/T 3102.1-1993 Quantities and units of space and time
  • GB/T 3102.10-1993 Quantities and units of nuclear reactions and ionizing radiations
  • GB/T 3102.11-1993 Mathematical signs and symbols for use in the physical sciences and technology
  • GB/T 3102.12-1993 Characteristic numbers
  • GB/T 3102.13-1993 Quantities and units of solid state physics
  • GB/T 3102.2-1993 Quantities and units of periodic and related pheno-mena
  • GB/T 3102.3-1993 Quantities and units of mechanics
  • GB/T 3102.4-1993 Quantities and units of heat
  • GB/T 3102.5-1993 Quantities and units of electricity and magnetism
  • GB/T 3102.6-1993 Quantities and units of light and related electromagnetic radiations
  • GB/T 3102.7-1993 Quantities and units of acoustics
  • GB/T 3102.8-1993 Quantities and units of physical chemistry and molecular physics
  • GB/T 3102.9-1993 Quantities and units of atomic and nuclear
  • IEC 61223-3-5 Corrigendum 1 - Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance and constancy tests - Imaging performance of computed tomography X-ray equipment*2022-06-08 Update

JJG 1026-2007 history

  • 2018 JJG 961-2017 Verification rules for X-ray radiation source of medical diagnostic spiral computed tomography (CT)
  • 2007 JJG 1026-2007 Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography (CT)

JJG 1026-2007 Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography (CT) was changed to JJG 961-2017 Verification rules for X-ray radiation source of medical diagnostic spiral computed tomography (CT).

Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography (CT)



Copyright ©2024 All Rights Reserved