Scope
This standard specifies the technical requirements and test methods for dynamic simulation tests of corrosion and scale inhibition properties of water treatment chemicals used in boilers that are coal-fired, oil-fired, gas-fired, and electric-heated at normal or low pressure. This standard applies to water treatment chemicals added to the boiler water of steam boilers and steam-water boilers with a rated pressure less than or equal to 2.5MPa using water as the medium, as well as fixed pressure hot water boilers and atmospheric pressure hot water boilers using water as the medium. The scale inhibition performance, the liquid phase corrosion inhibition performance in the furnace, the vapor phase corrosion inhibition performance in the furnace and the pipe corrosion inhibition performance of steam condensate water were measured. The measurement of scale and corrosion inhibition performance of water treatment equipment outside the furnace and physical methods of boiler water processors can also be used as a reference.

HG/T 3924-2007 Referenced Document

  • GB 150 Pressure Vessels (Bound Edition)*2024-04-18 Update
  • GB 1576 Water quality for industrial boilers
  • GB 6913.2 Determination of Phosphate Total Inorganic Phosphate
  • GB 6913.3 Determination of Phosphate Total Phosphate
  • GB/T 15451 Industrial circulating cooling water Determination of total and composite alkalinity
  • GB/T 18175 Determination of corrosion inhibition performance of water treatment agents.Rotation specimen method*2014-07-08 Update
  • GB/T 6903 Analysis of water used in boiler and cooling system—General rule*2022-03-09 Update
  • GB/T 6904.1 Methods for analysis of water for boiler and for cooling--The determination of pH--The glass electrode method
  • GB/T 6905.1 Methods for analysis of water for boiler and for cooling--The determination of chloride--The Mohr method
  • GB/T 6907 Analysis of water used in boiler and cooling system—Sampling method of water*2022-03-09 Update
  • GB/T 6908 Analysis of water used in boiler and cooling system.Determination of electrical conductivity*2018-06-07 Update
  • GB/T 6909.1 Methods for analysis of water for boiler and for cooling--The determination of hardness--High hardness
  • GB/T 6910 Methods for analysis of water for boiler and for cooling.Determination of calcium.Complexometric titration
  • GB/T 6911.1 Methods for analysis of water for boiler and for cooling--The determination of sulfate--Gravimetric method
  • HG/T 3523 Technical conditions of standard corrosion spool of chemical treatment in cooling water*2008-04-23 Update