SAE ARP594D-1990
FUEL PUMP THERMAL SAFETY DESIGN

Standard No.
SAE ARP594D-1990
Release Date
1990
Published By
Society of Automotive Engineers (SAE)
Status
Replace By
SAE ARP594D-2007
Latest
SAE ARP594F-2022
Scope
These recommendations cover only those design factors which might cause the pump motor or pump housing to act as an autogenous or spark-ignition source for explosive fuel vapors within the airplane tank. This Aerospace Recommended Practice (ARP) recommends fuel booster pump design requirements commensurate with the presently known state-of-the-art, relating to the prevention of autogenous ignition of explosive fuel vapors and the confinement of autogenous or spark-initiated flames by means of flame-suppressing devices.