JIS H 7310:2006
Superconductivity -- AC loss measurements -- Total AC loss measurement of Cu/Nb-Ti composite superconducting wires exposed to a transverse alternating magnetic field by a pickup coil method

Standard No.
JIS H 7310:2006
Release Date
2006
Published By
Japanese Industrial Standards Committee (JISC)
Status
 2013-01
Replace By
JIS H 7310:2013
Latest
JIS H 7310:2013
Scope
This standard specifies a method for measuring the total AC loss in a niobium-titanium composite superconducting wire in an AC transverse magnetic field with a varying magnetic field frequency range of 0.005 to 1 Hz using the big-up coil method.

JIS H 7310:2006 history

  • 2013 JIS H 7310:2013 Superconductivity -- AC loss measurements -- Total AC loss measurement of round superconducting wires exposed to a transverse alternating magnetic field at liquid helium temperature by a pickup coil method
  • 2006 JIS H 7310:2006 Superconductivity -- AC loss measurements -- Total AC loss measurement of Cu/Nb-Ti composite superconducting wires exposed to a transverse alternating magnetic field by a pickup coil method