BS EN 15058:2006
Stationary source emissions - Determination of the mass concentration of carbon monoxide (CO) - Reference method: non-dispersive infrared spectrometry

Standard No.
BS EN 15058:2006
Release Date
2006
Published By
British Standards Institution (BSI)
Status
 2017-01
Replace By
BS EN 15058:2017
Latest
BS EN 15058:2017
Scope
This European Standard specifies the Standard Reference Method (SRM) for sampling, and determining carbon monoxide content in ducts and stacks emitting to atmosphere. It describes the Non Dispersive Infra-Red (NDIR) analytical technique, including the sampling system and sample gas conditioning system, to determine CO in flue gases. This European Standard is the reference method for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory purposes or other purposes. To be used as the SRM, it is necessary to demonstrate that the performance characteristics of the method are lower than the performance criteria defined in this European standard and that the overall uncertainty of the method is less than ± 6 % relative at the daily Emission Limit Value (ELV). NOTE When the NDIR method is used as an AMS, refer to EN 14181 and other relevant standards provided by CEN TC 264. It is necessary for anybody who would like to use an Alternative Method instead of this Standard Reference Method to work out the demonstration of the equivalence according to the Technical Specification TS 14793, providing that his capability to carry out this demonstration is officially recognised by his national accreditation body or law. This Standard Reference Method has been evaluated during field tests on waste incineration, co-incineration installations and large combustion plants. It has been validated for CO concentrations with sampling periods of 30 min in the range of 0 mg/m3 to 400 mg/m3 for large combustion plants and 0 mg/m3 – 740 mg/m3 for waste and co-incineration. For waste incineration plants, Council Directive 2000/76/EC lays down emission values which are expressed in mg/m3, on dry basis at a specified value of O2 and at reference conditions of 273 K and 101,3 kPa.

BS EN 15058:2006 Referenced Document

  • EN ISO 14956 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty ISO 14956: 2002
  • ISO 5725-2 Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method*2019-12-06 Update
  • ISO 5725-6:1994 Accuracy (trueness and precision) of measurement methods and results - Part 6: Use in practice of accuracy values

BS EN 15058:2006 history

  • 2017 BS EN 15058:2017 Stationary source emissions. Determination of the mass concentration of carbon monoxide. Standard reference method: non-dispersive infrared spectrometry
  • 2006 BS EN 15058:2006 Stationary source emissions - Determination of the mass concentration of carbon monoxide (CO) - Reference method: non-dispersive infrared spectrometry