BS EN 14792:2005
Stationary source emissions - Determination of mass concentration of nitrogen oxides (NOx) - Reference method: Chemiluminescence

Standard No.
BS EN 14792:2005
Release Date
2006
Published By
British Standards Institution (BSI)
Status
 2017-01
Replace By
BS EN 14792:2017
Latest
BS EN 14792:2017
Replace
03/312903 DC-2003
Scope
This European Standard describes the chemiluminescence method, including the sampling and the gas conditioning system, to determine the NO/NO2/NOx concentrations in flue gases emitted from ducts and stacks to atmosphere. This European Standard is the Standard Reference Method (SRM) for periodic monitoring and for calibration or control of Automatic Measuring Systems (AMS) permanently installed on a stack, for regulatory or other purposes such as calibration. To be used as the SRM, the user shall demonstrate that the performance characteristics of the method are better than the performance criteria defined in this European Standard and that the overall uncertainty of the method is less than ± 10 % relative at the daily Emission Limit Value (ELV). NOTE When the chemiluminescence method is the measurement principle used for AMS, reference should be made to EN 14181 and other relevant standards provided by CEN TC 264. An Alternative Method to this SRM may be used provided that the user can demonstrate equivalence according to the Technical Specification CEN TS 14793, to the satisfaction of his national accreditation body or law. This SRM has been evaluated during field tests on waste incineration, co-incineration and large combustion installations. It has been validated for sampling periods of 30 min in the range of 0 mg NO2/m3 to 1 300 mg NO2/m3 for large combustion plants and 0 mg NO2/m3 to 400 mg NO2/m3 for waste incineration, according to emission limit values (ELVs) laid down in the following Council Directives:  Council Directive 2001/80/EC on the limitation of emissions of certain pollutants into the air from large combustion plants;  Council Directive 2000/76/EC on waste incineration plants. The ELVs for NOx (NO + NO2) in EU directives are expressed in mg NO2/m3, on dry basis, at a reference value for O2 and at the reference conditions (273 K and 101,3 kPa).

BS EN 14792:2005 Referenced Document

  • EN ISO 14956 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty ISO 14956: 2002

BS EN 14792:2005 history

  • 2017 BS EN 14792:2017 Stationary source emissions. Determination of mass concentration of nitrogen oxides. Standard reference method. Chemiluminescence
  • 2006 BS EN 14792:2005 Stationary source emissions - Determination of mass concentration of nitrogen oxides (NOx) - Reference method: Chemiluminescence



Copyright ©2024 All Rights Reserved