IEC 60332-3-23:2000
Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables; Category B

Standard No.
IEC 60332-3-23:2000
Release Date
2000
Published By
International Electrotechnical Commission (IEC)
Status
 2009-02
Replace By
IEC 60332-3-23:2000/AMD1:2008
Latest
IEC 60332-3-23:2018 RLV
Replace
IEC 20/405/FDIS:2000 IEC/TR2 60332-3:1992
Scope
Parts 31, 32, 33, 34, 35 and 36 of GB/T 18380 specify a test method to evaluate the ability of vertically installed bundles of wires, cables or optical cables to inhibit the vertical spread of flames under specified conditions. Note: In this section the term "wires and cables" includes all insulated cables with metallic conductors used for the transmission of energy or signals. This test is used for type approval testing. See Appendix A for the selection requirements for test cables. Flame spread is determined by the extent of damage to the cable specimen. This test procedure can be used to verify the ability of a cable to inhibit the spread of flames. This part of GB/T 18380 applies to Category B. The cable is installed on the test steel ladder so that the total volume of the non-metallic material contained in the sample is 3 5 L/m. The time for offering fire is 40 mln. The cable is installed in front of a standard steel ladder. Category B is used to evaluate the volume content of medium non-metallic materials. Recommended performance requirements are given in Appendix B.

IEC 60332-3-23:2000 Referenced Document

  • GB/T 16499-1996 Guide to the drafting of electrical safety standards
  • GB/T 18380.31-2008 Test on electric and optical fibre cables under fire conditions.Part 31:Test for vertical flame spread of vertically-mounted bunched wires or cables.Apparatus*2008-06-26 Update
  • GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric and optical cables.Part13:Methods for general application.Measurement for determining the density.Water absorption tests.Shrinkage test*2008-06-26 Update
  • IEC 60695-4:1993 Fire hazard testing; part 4: terminology concerning fire test

IEC 60332-3-23:2000 history

  • 0000 IEC 60332-3-23:2018 RLV
  • 2009 IEC 60332-3-23:2009 Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B
  • 2008 IEC 60332-3-23:2000/AMD1:2008 Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B
  • 2000 IEC 60332-3-23:2000 Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables; Category B



Copyright ©2024 All Rights Reserved