IEC 60255-22-3:2000
Electrical relays - Part 22-3: Electrical disturbance tests for measuring relays and protection equipment; Radiated electromagnetic field disturbance tests

Standard No.
IEC 60255-22-3:2000
Release Date
2000
Published By
International Electrotechnical Commission (IEC)
Status
 2013-05
Replace By
IEC 60255-22-3:2007
Latest
IEC 60255-22-3:2007
Scope
This part of IEC 60255 is based on 1EC 61000-4-3, referring to that publication where applicable, and specifies the general requirements for radiated electromagnetic field disturbance tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the EUT (equipment under test) will operate correctly when energised and subjected to an electromagnetic field from a radiation source operating within the frequency range 80 MHz to 1000 MHz. NOTE 1 The product standard IEC 60255-22-6 (based on IEC 61000-4-6) establishes the immunity of measuring relays and protection equipment over the frequency range of 0,15 MHz to 80 MHz. Also, amendment 1 (subclause 5.2) to IEC 61000-4-3 proposes to include frequencies up to 2 GHz to test for immunity against devices such as portable digital telephones. NOTE 2 The test methods defined in this standard are structured for the primary objective of establishing adequate repeatability of results at various test facilities for qualitative analysis of effects. The test methods using a portable transmitter are not taken into consideration here because the EMC directive now specifies a sweep test, calibrated field strengths must be used and the portable transmitter test is not generally reproducible. The requirements specified in this standard are applicable to measuring relays and protection equipment in an unused condition, and all tests specified are type tests only. note: * (specified in the first edition (1989) of this standard)

IEC 60255-22-3:2000 history

  • 2007 IEC 60255-22-3:2007 Measuring relays and protection equipment - Part 22-3: Electrical disturbance tests - Radiated electromagnetic field immunity
  • 2000 IEC 60255-22-3:2000 Electrical relays - Part 22-3: Electrical disturbance tests for measuring relays and protection equipment; Radiated electromagnetic field disturbance tests
  • 1989 IEC 60255-22-3:1989 Electric relays; part 22: electrical disturbance tests for measuring relays and protection equipment; section three: radiated electromagnetic field disturbance tests