IEC 60999-1:1999
Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm<(hoch)2> up to 35 mm<(hoch)2>

Standard No.
IEC 60999-1:1999
Release Date
1999
Published By
International Electrotechnical Commission (IEC)
Latest
IEC 60999-1:1999
Replace
IEC 23F/108/FDIS:1999 IEC 60999-1:1990
Scope
This part of IEC 60999 applies to screw-type and screwless-type clamping units for connecting devices, either as separate entities or as integral parts of equipment, for the connection of electrical copper conductors (complying with IEC 60228), rigid (solid or stranded) and/or flexible, having a cross-sectional area of 0,2 mm up to and including 35 mm and equivalent AWG sizes with a rated voltage not exceeding 1 000 V a.c. with a frequency up to and including 1 000 Hz, and 1 500 V d.c. It applies to clamping units primarily suitable for connecting unprepared conductors. This standard does not apply to clamping units a) for connection by crimping or soldering; b) for data and signalling circuits; c) for flat quick-connect terminations, insulation-piercing connecting devices and twist-on connecting devices, which are covered by IEC 61210 [3], IEC 60998-2-3 [1] and IEC 60998-2-4 [2] respectively. note: 1) Figures in square brackets refer to the bibliography.

IEC 60999-1:1999 history

  • 1999 IEC 60999-1:1999 Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm<(hoch)2> up to 35 mm<(hoch)2>
  • 1970 IEC 60999-1:1990/COR1:1995 Corrigendum 1 - Connecting devices - Safety requirements for screw-type and screwless-type clamping units for electrical copper conductors - Part 1: General requirements and particular requirements for conductors from 0,5 mm2 up to 35 mm2 (included)
  • 1990 IEC 60999-1:1990 Connecting devices - Safety requirements for screw-type and screwless-type clamping units for electrical copper conductors - Part 1: General requirements and particular requirements for conductors from 0,5 mm<(hoch)2> up to 35 mm<(hoch)2> (included)
Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm<(hoch)2> up to 35 mm<(hoch)2>