UL 514A BULLETIN-2009
UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: August 24@ 2009)

Standard No.
UL 514A BULLETIN-2009
Release Date
2009
Published By
Underwriters Laboratories (UL)
Status
 2011-06
Replace By
UL 514A BULLETIN-2011
Latest
UL 514A BULLETIN-2022
Scope
This standard applies to metallic OUTLET BOXES@ flush-DEVICE BOXES@ FLOOR BOXES@ CONCRETE BOXES@ EXTENSION RINGS@ covers@ CONDUIT BODIES@ BAR HANGERS@ bar-hanger assemblies@ and all accessories whose principal function is for support of boxes. The products covered by this standard are intended for installation in accordance with the National Electrical Code (NEC)@ NFPA 70@ the Canadian Electrical Code (CEC)@ Part I@ and the Standard for Electrical Installations@ NOM-001-SEDE. In Canada@ CONDUIT BODIES are not evaluated as OUTLET BOXES; they are fittings. Requirements in this standard for CONDUIT BODIES intended for use as OUTLET BOXES do not apply in Canada. This standard also applies to marine application metallic OUTLET BOXES@ flush-DEVICE BOXES@ special purpose boxes@ EXTENSION RINGS@ and covers. This standard also applies to marine products intended for installation in accordance with the manufacturer's instructions and the applicable requirements of the United States Coast Guard (USCG)@ IEEE Recommended Practice for Electric Installation on Shipboard@ IEEE Standard 45; the American Boat and Yacht Council (ABYC); the Standard for Pleasure and Commercial Motor Craft@ NFPA 302; and the Canadian Electrical Code (CEC)@ Part I. This standard does not apply to cabinets and cutout boxes@ boxes@ and covers intended for use with raceway systems for surface wiring other than rigid or flexible conduit or electrical metallic tubing. This standard does not apply to boxes having a volume of more than 1640 cm? (100 in?)@ other than multiple-gang boxes@ flush-DEVICE BOXES@ and CONDUIT BODIES intended for the larger trade sizes of conduit. This standard does not apply to cover plates for flush-mounted wiring devices. This standard does not apply to OUTLET BOXES or OUTLET BOX COVERS for use in hazardous (classified) locations as defined in the National Electrical Code (NEC)@ NFPA 70@ the rules of the Canadian Electrical Code (CEC)@ Part I@ and the Standard for Electrical Installations@ NOM-001-SEDE.

UL 514A BULLETIN-2009 history

  • 2022 UL 514A BULLETIN-2022 UL Standard for Safety Metallic Outlet Boxes
  • 2018 UL 514A CRD-2018 UL Standard for Safety Metallic Outlet Boxes - Section / Paragraph Reference: 10.3.3 Subject: Slots in Adjustable Metal Outlet Boxes for Use only With Bar Hanger Assemblies (Edition 11; February 1@ 2013)
  • 2017 UL 514A CRD-2017 UL Standard for Safety Metallic Outlet Boxes - Section / Paragraph Reference: 10.3.3 Subject: Clarification of the Calculation Method for Open Hole Area In Boxes with Removable Faces (Edition 11; February 1@ 2013)
  • 2017 UL 514A BULLETIN-2017 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: March 27@ 2017)
  • 2017 UL 514A-2017 UL Standard for Safety Metallic Outlet Boxes (Eleventh Edition; Reprint with Revisions Through and Including August 11@ 2017)
  • 2016 UL 514A BULLETIN-2016 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: December 2@ 2016)
  • 2015 UL 514A BULLETIN-2015 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: May 18@ 2015)
  • 2014 UL 514A BULLETIN-2014 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: October 13@ 2014)
  • 2013 UL 514A-2013 UL Standard for Safety Metallic Outlet Boxes (Eleventh Edition; Reprint with Revisions Through and Including August 11@ 2017)
  • 2012 UL 514A CRD-2012 UL Standard for Safety Metallic Outlet Boxes - Section/Paragraph Reference: Sections 3@ 5@ 6@ 9@ 10@ 12@ Table 16 Subject: Adjustable Mud Ring Supercedes prior Certification Requirement Decision issued April 12@ 2011 (Edition 10; February 16@ 2004)
  • 2012 UL 514A BULLETIN-2012 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: October 22@ 2012)
  • 2011 UL 514A CRD-2011 UL Standard for Safety Metallic Outlet Boxes - Section/Paragraph Reference: Subject: Addition of requirements for the evaluation of a through wall device or outlet box (Edition 10; February 16@ 2004)
  • 2011 UL 514A BULLETIN-2011 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: July 25@ 2011)
  • 2009 UL 514A BULLETIN-2009 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: August 24@ 2009)
  • 2008 UL 514A CRD-2008 UL Standard for Safety Metallic Outlet Boxes - Section/Paragraph Reference: Clause 9.5.1.3.1 Subject: Proposed revision to Clause 9.5.1.3.1 of UL 514A (Edition 10; February 16@ 2004)
  • 2008 UL 514A BULLETIN-2008 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: February 6@ 2009)
  • 2007 UL 514A BULLETIN-2007 UL Standard for Safety Metallic Outlet Boxes (COMMENTS DUE: June 04@ 2007)
  • 2006 UL 514A BULLETINS-2006 UL Standard for Safety Metallic Outlet Boxes (08/25/2006 (16p); 04/03/2006 (16p))
  • 2004 UL 514A-2004 Metallic outlet boxes
  • 2003 UL 514A BULLETINS-2003 11/18/2003 (68p)
  • 2003 UL 514A BULLETIN-2003 UL Standard for Safety Metallic Outlet Boxes
  • 2002 UL 514A BULLETINS-2002 05/24/2002 (88p)
  • 2002 UL 514A BULLETIN-2002 UL Standard for Safety Metallic Outlet Boxes
  • 2001 UL 514A BULLETINS-2001 11/2/2001 (4p), 5/23/2001 (2p), 2/13/2001 (4p)
  • 2000 UL 514A BULLETINS-2000 UL Standard for Safety Metallic Outlet Boxes (10/25/2000 (12p); 03/23/2000 (8p))
  • 1996 UL 514A-1996 Metallic outlet boxes
  • 1991 UL 514A-1991 Metallic outlet boxes



Copyright ©2024 All Rights Reserved