T/GDWCA 0028-2018 Special employed FEP and PFA insulated high temperature fitting wires of rated voltages up to and including 450/750 V (English Version)
1. Structure 1. The insulation should be tightly wrapped around the conductor core and easy to peel off without damaging the insulation layer and plating. 2. The concentricity of the wire should be no less than 80%. 3. The braiding density of the wire braiding shield should not be less than 85%, etc. 2. Finished cable test 1. Wire core insulation resistance: should not be less than 1.5×103MΩ·km. 2. The nominal cross-sectional area of the conductor is ≥0.5mm2. The sample is a single wire removed from the conductor. The nominal cross-sectional area of the conductor is <0.5mm2. The sample is a complete conductor. When testing the entire conductor, the measured value shall be taken from the first sample. Reading when a single wire breaks. 3. Execute in accordance with the DZ-3 method in GB/T12666.2-2008, etc.