ASTM E1664-19
Standard Classification for Serviceability of an Office Facility for Layout and Building Factors

Standard No.
ASTM E1664-19
Release Date
2019
Published By
American Society for Testing and Materials (ASTM)
Latest
ASTM E1664-19
Scope
1.1 This classification covers matched sets of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for layout and building factors. 1.2 Within that aspect of serviceability, each matched set of scales, shown in Figs. 1-12, are for classifying one topic of serviceability. Each topic is typically broken down into two or more demand functions or supply features. Each paragraph in an Occupant Requirement Scale (see Figs. 1-12) summarizes one level of serviceability on that function, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1-12) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability. 1.3 The entries in the Facility Rating Scale (see Figs. 1-12) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing. 1.4 This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared. 1.5 This classification indicates what would cause a facility to be rated at a certain level of serviceability but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1679. The scales in this classification are complimentary to and compatible with Practice E1679. Each requires the other. 1.6 The scales are intended to identify the levels of various requirements unique to a particular user, and the serviceability (capability) of a building to meet those requirements. The scales thus supplement rather than include code requirements. It remain the responsibility of designers, builders, and building managers to meet applicable code requirements relative to their respective roles in facility design, construction, and ongoing management. 1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E1664-19 Referenced Document

  • ASTM E1662 Standard Classification for Serviceability of an Office Facility for Sound and Visual Environment
  • ASTM E1679 Standard Practice for Setting the Requirements for the Serviceability of a Building or Building-Related Facility
  • ASTM E1836/E1836M Standard Practice for Building Floor Area Measurements for Facility Management*2024-04-22 Update
  • ASTM E2320 Standard Classification for Serviceability of an Office Facility for Thermal Environment and Indoor Air Conditions*2019-11-15 Update
  • ASTM E2619/E2619M Standard Practice for Measuring and Calculating Building Loss Features That Take Up Floor Area in Buildings
  • ASTM E631 Standard Terminology of Building Constructions
  • ISO 6240 Performance standards in building; Contents and presentation

ASTM E1664-19 history

  • 2019 ASTM E1664-19 Standard Classification for Serviceability of an Office Facility for Layout and Building Factors
  • 2018 ASTM E1664-95a(2018) Standard Classification for Serviceability of an Office Facility for Layout and Building Factors
  • 1995 ASTM E1664-95a(2012) Standard Classification for Serviceability of an Office Facility for Layout and Building Factors
  • 1995 ASTM E1664-95a(2005) Standard Classification for Serviceability of an Office Facility for Layout and Building Factors
  • 1995 ASTM E1664-95a(1999) Standard Classification for Serviceability of an Office Facility for Layout and Building Factors
Standard Classification for Serviceability of an Office Facility for Layout and Building Factors<rangeref></rangeref >