1 Scope
This part of IEC 60754 specifies the apparatus and procedure for the determination of the amount of halogen
acid gas, other than hydrofluoric acid, evolved during the combustion of compounds
based on halogenated polymers and compounds containing halogenated additives taken
from electric or optical fibre cable constructions.
NOTE 1 This test method is not able to determine hydrofluoric acid. A suitable method may
be found in IEC 60684‑2.
NOTE 2 This test method may be used to test materials to be used in cable manufacture, but
a declaration of cable performance should not be made based on such a test.
NOTE 3 The relevant cable standard should indicate which components of the cable should be
tested.
NOTE 4 For the purposes of this standard, the term “electric cable” covers all insulated
metallic conductor cables used for the conveyance of energy or signals.
The method specified in this standard is intended for the testing of individual components
used in a cable construction. The use of this method will enable the verification
of requirements which are stated in the appropriate cable specification for individual
components of a cable construction.
NOTE 5 By agreement between the producer and purchaser, the...
BS EN 60754-1:2014+A1:2020 history
2020BS EN 60754-1:2014+A1:2020 Test on gases evolved during combustion of materials from cables - Determination of the halogen acid gas content
2014BS EN 60754-1:2014 Test on gases evolved during combustion of materials from cables. Determination of the halogen acid gas content
1999BS EN 50267-2-3:1999 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity