BS EN 55016-1-5:2015+A1:2017
Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus. Antenna calibration sites and reference test sites for 5 MHz to 18 GHz

Standard No.
BS EN 55016-1-5:2015+A1:2017
Release Date
2020
Published By
British Standards Institution (BSI)
Status
Replace By
BS EN 55016-1-5:2015+A1:2017(2020)
Latest
BS EN 55016-1-5:2015+A1:2017(2020)
Scope
1   Scope This part of CISPR 16 specifies the requirements for calibration sites in the frequency range 5 MHz to 18 GHz used to perform antenna calibrations according to CISPR 16-1-6. It also specifies the requirements for reference test sites ( REFTS ) that are used for the validation of compliance test sites ( COMTS ) in the frequency range 30 MHz to 1 000 MHz according to CISPR 16-1-4. It has the status of a basic EMC standard in accordance with IEC Guide 107, Electromagnetic compatibility – Guide to the drafting of electromagnetic compatibility publications. Measurement instrumentation specifications are given in CISPR 16-1-1 [1] 1 and CISPR 16-1-4. Further information and background on uncertainties in general is given in CISPR 16-4 [3], which can also be helpful in establishing uncertainty estimates for the calibration processes of antennas and site validation measurements.

BS EN 55016-1-5:2015+A1:2017 history

  • 0000 BS EN 55016-1-5:2015+A1:2017(2020)
  • 2020 BS EN 55016-1-5:2015+A1:2017 Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus. Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
  • 2015 BS EN 55016-1-5:2015 Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Antenna calibration sites and reference test sites for 5 MHz to 18 GHz
  • 2005 BS EN 55016-1-5:2004+A1:2012 Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Antenna calibration test sites for 30 MHz to 1000 MHz
  • 2005 BS EN 55016-1-2+A2:2005 Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Ancillary equipment. Conducted disturbances
  • 2005 BS EN 55016-1-5:2004 Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Antenna calibration test sites for 30 MHz to 1 000 MHz
  • 0000 BS CISPR 16-1:2000
  • 0000 BS CISPR 16-1:1999



Copyright ©2024 All Rights Reserved