ASTM E1543-14(2022)
Standard Practice for Noise Equivalent Temperature Difference of Thermal Imaging Systems

Standard No.
ASTM E1543-14(2022)
Release Date
2022
Published By
American Society for Testing and Materials (ASTM)
Latest
ASTM E1543-14(2022)
Scope
1.1 This practice covers the determination of the noise equivalent temperature difference (NETD; NE∆T) of thermal imaging systems of the conventional forward-looking infrared (FLIR) or other types that utilize an optical-mechanical scanner; it does not include charge-coupled devices or pyroelectric vidicons. 1.2 Parts of this practice have been formulated under the assumption of a photonic detector(s) at a standard background temperature of 295 °K (22 °C). Besides nonuniformity, examinations made at other background temperatures may result in impairment of precision and bias. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ASTM E1543-14(2022) Referenced Document

  • ASTM E1213 Standard Test Method for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
  • ASTM E1316 Standard Terminology for Nondestructive Examinations*2024-02-01 Update

ASTM E1543-14(2022) history

  • 2022 ASTM E1543-14(2022) Standard Practice for Noise Equivalent Temperature Difference of Thermal Imaging Systems
  • 2018 ASTM E1543-14(2018) Standard Practice for Noise Equivalent Temperature Difference of Thermal Imaging Systems
  • 2014 ASTM E1543-14 Standard Practice for Noise Equivalent Temperature Difference of Thermal Imaging Systems
  • 2000 ASTM E1543-00(2011) Standard Test Method for Noise Equivalent Temperature Difference of Thermal Imaging Systems
  • 2000 ASTM E1543-00(2006) Standard Test Method for Noise Equivalent Temperature Difference of Thermal Imaging Systems
  • 2000 ASTM E1543-00 Standard Test Method for Noise Equivalent Temperature Difference of Thermal Imaging Systems
Standard Practice for Noise Equivalent Temperature Difference of Thermal Imaging Systems



Copyright ©2024 All Rights Reserved