ASTM D6971-22 Standard Test Method for Measurement of Hindered Phenolic and Aromatic Amine Antioxidant Content in Non-zinc Turbine Oils by Linear Sweep Voltammetry
1.1 This test method covers the voltammetric determination of hindered phenol and aromatic amine antioxidants in new or in-service type non-zinc turbine oils in concentrations from
0.0075 % by mass up to concentrations found in new oils by measuring the amount of current flow at a specified voltage in the produced voltammogram.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.3 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
ASTM D6971-22 Referenced Document
ASTM D1193 Standard Specification for Reagent Water
ASTM D2272 Standard Test Method for Oxidation Stability of Steam Turbine Oils by Rotating Pressure Vessel
ASTM D4057 Standard Practice for Manual Sampling of Petroleum and Petroleum Products
ASTM D4175 Standard Terminology Relating to Petroleum Products, Liquid Fuels, and Lubricants*, 2023-07-01 Update
ASTM D4378 Standard Practice for In-Service Monitoring of Mineral Turbine Oils for Steam and Gas Turbines
ASTM D6224 Standard Practice for In-Service Monitoring of Lubricating Oil for Auxiliary Power Plant Equipment
ASTM D6810 Standard Test Method for Measurement of Hindered Phenolic Antioxidant Content in Non-Zinc Turbine Oils by Linear Sweep Voltammetry
ISO 6743 Lubricants, industrial oils and related products (class L) - Classification - Part 9: Family X (Greases)
ASTM D6971-22 history
2022ASTM D6971-22 Standard Test Method for Measurement of Hindered Phenolic and Aromatic Amine Antioxidant Content in Non-zinc Turbine Oils by Linear Sweep Voltammetry
2009ASTM D6971-09(2014) Standard Test Method for Measurement of Hindered Phenolic and Aromatic Amine Antioxidant Content in Non-zinc Turbine Oils by Linear Sweep Voltammetry
2009ASTM D6971-09 Standard Test Method for Measurement of Hindered Phenolic and Aromatic Amine Antioxidant Content in Non-zinc Turbine Oils by Linear Sweep Voltammetry
2004ASTM D6971-04 Standard Test Method for Measurement of Hindered Phenolic and Aromatic Amine Antioxidant Content in Non-zinc Turbine Oils by Linear Sweep Voltammetry